SN8P1700  
8-bit micro-controller build-in 12-bit ADC  
INT0 (P0.0) INTERRUPT OPERATION  
The INT0 is triggered by falling edge. When the INT0 trigger occurs, the P00IRQ will be set to “1” however the P00IEN  
is enable or disable. If the P00IEN = 1, the trigger event will make the P00IRQ to be “1” and the system enter interrupt  
vector. If the P00IEN = 0, the trigger event will make the P00IRQ to be “1” but the system will not enter interrupt vector.  
Users need to care for the operation under multi-interrupt situation.  
Example: INT0 interrupt request setup.  
B0BSET  
B0BCLR  
B0BSET  
FP00IEN  
FP00IRQ  
FGIE  
; Enable INT0 interrupt service  
; Clear INT0 interrupt request flag  
; Enable GIE  
Example: INT0 interrupt service routine.  
ORG  
JMP  
8
; Interrupt vector  
INT_SERVICE  
INT_SERVICE:  
B0XCH  
PUSH  
A, ACCBUF  
; B0XCH doesn’t change C, Z flag  
; Push  
B0BTS1  
JMP  
FP00IRQ  
EXIT_INT  
; Check P00IRQ  
; P00IRQ = 0, exit interrupt vector  
B0BCLR  
FP00IRQ  
; Reset P00IRQ  
.
.
.
.
; INT0 interrupt service routine  
EXIT_INT:  
POP  
; Pop  
B0XCH  
A, ACCBUF  
; Restore ACC value.  
RETI  
; Exit interrupt vector  
Note: The PUSH and POP instruction only save L,H,R,Z,Y,X,PFLAG and RBANK registers but A register.  
User must save register A by B0XCH instruction when PUSH command is used.  
INT1 (P0.1) INTERRUPT OPERATION  
The INT1 is triggered by falling edge. When the INT1 trigger occurs, the P01IRQ will be set to “1” however the P01IEN  
is enable or disable. If the P01IEN = 1, the trigger event will make the P01IRQ to be “1” and the system enter interrupt  
vector. If the P01IEN = 0, the trigger event will make the P01IRQ to be “1” but the system will not enter interrupt vector.  
Users need to care for the operation under multi-interrupt situation.  
Example: INT1 interrupt request setup.  
B0BSET  
B0BCLR  
B0BSET  
FP01IEN  
FP01IRQ  
FGIE  
; Enable INT1 interrupt service  
; Clear INT1 interrupt request flag  
; Enable GIE  