JUMP TABLE DESCRIPTION  
The jump table operation is one of multi-address jumping function. Add low-byte program counter (PCL) and ACC  
value to get one new PCL. The new program counter (PC) points to a series jump instructions as a listing table. The  
way is easy to make a multi-stage program.  
When carry flag occurs after executing of “ADD PCL, A”, it will not affect PCH register. Users have to check if the jump  
table leaps over the ROM page boundary or the listing file generated by SONIX assembly software. If the jump table  
leaps over the ROM page boundary (e.g. from xxFFH to xx00H), move the jump table to the top of next program  
memory page (xx00H). Here one page mean 256 words.  
Example : If PC = 0323H (PCH = 03HPCL = 23H)  
ORG  
0X0100  
; The jump table is from the head of the ROM boundary  
B0ADD  
JMP  
JMP  
JMP  
JMP  
PCL, A  
; PCL = PCL + ACC, the PCH can’t be changed.  
; ACC = 0, jump to A0POINT  
; ACC = 1, jump to A1POINT  
; ACC = 2, jump to A2POINT  
; ACC = 3, jump to A3POINT  
A0POINT  
A1POINT  
A2POINT  
A3POINT  
In following example, the jump table starts at 0x00FD. When execute B0ADD PCL, A. If ACC = 0 or 1, the jump  
table points to the right address. If the ACC is larger then 1 will cause error because PCH doesn't increase one  
automatically. We can see the PCL = 0 when ACC = 2 but the PCH still keep in 0. The program counter (PC) will  
point to a wrong address 0x0000 and crash system operation. It is important to check whether the jump table  
crosses over the boundary (xxFFH to xx00H). A good coding style is to put the jump table at the start of ROM  
boundary (e.g. 0100H).  
Example: If “jump table” crosses over ROM boundary will cause errors.  
ROM Address  
.
.
.
.
.
.
B0ADD  
JMP  
JMP  
JMP  
JMP  
.
PCL, A  
; PCL = PCL + ACC, the PCH can’t be changed.  
; ACC = 0  
; ACC = 1  
; ACC = 2 jump table cross boundary here  
; ACC = 3  
0X00FD  
0X00FE  
0X00FF  
0X0100  
0X0101  
.
A0POINT  
A1POINT  
A2POINT  
A3POINT  
.
.
SONIX provides a macro for safe jump table function. This macro will check the ROM boundary and move the jump  
table to the right position automatically. The side effect of this macro is maybe wasting some ROM size. Notice the  
maximum jmp table number for this macro is limited under 254.  
@JMP_A  
MACRO  
IF  
VAL  
(($+1) !& 0XFF00) !!= (($+(VAL)) !& 0XFF00)  
JMP  
($ | 0XFF)  
($ | 0XFF)  
ORG  
ENDIF  
ADD  
PCL, A  
ENDM  
Note: “VAL” is the number of the jump table listing number.  