Surface Mount 2-Electrode Gas Discharge Tube (GDT)
UN1206 Series
Electrical Rating
Item
Test Condition / Description
Requirement
DC Spark-over Voltage
The voltage is measured with a slowly rate of rise dv / dt=100V/s
Impulse Spark-over
Voltage
The maximum impulse spark-over voltage is measured with a rise time of
dv / dt=100V//μs or 1KV/μs
The resistance of gas tube shall be measured each terminal each other terminal,
please see above spec.
Insulation Resistance
Capacitance
The capacitance of gas tube shall be measured each terminal to each other
terminal.
Test frequency :1MHz
The maximum current applying a waveform of 8/20μs that can be applied across
the terminals of the gas tube. One hour after the test is completed, re-testing of the
DC spark-over voltage does not exceed ±40% of the nominal DC spark-over
voltage. Dwell time between pulses is 3 minutes.
To meet
the specified
value
1.0
0.9
Nominal Impulse
Discharge Current
0.5
0.1
0.0
T
8μsec
20μsec
30% Max
Recommended soldering profile
Reflow Condition
Pb - Free assembly
150°C
-Temperature Min (Ts(min)
)
-Temperature Max (Ts(max)
- Time (min to max) (ts)
TP
Pre Heat
)
200°C
Critical Zone
TL to TP
Ramp-up
60 -180 Seconds
TL
TS(max)
Average ramp up rate ( Liquidus Temp TL)
to peak
3°C/second max
Ramp-down
TS(max) to TL - Ramp-up Rate
5°C/second max
217°C
TS(min)
- Temperature (TL) (Liquidus)
Reflow
Preheat
- Time (min to max) (ts)
60 -150 Seconds
260 +0/-5°C
Peak Temperature (TP)
25
Time to peak temperature
Time
(t 25℃ to peak)
Time within 5°C of actual peak
Temperature (tp)
10 - 30 Seconds
Ramp-down Rate
6°C/second max
8 minutes Max
260°C
Time 25°C to peak Temperature (TP)
Do not exceed
SOCAY Electronics Co., Ltd.
www.socay.com
@SOCAY Electronics Co., Ltd. 2014
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Revision March 6, 2014
3 / 4