USB 2.0 Hi-Speed Hub Controller  
Datasheet  
Table 8.1 Hub Configuration Options (continued)  
CFG_SEL[2]  
CFG_SEL[1]  
CFG_SEL[0]  
DESCRIPTION  
1
0
0
Internal Default Configuration with the following over-rides  
„
„
„
„
„
Dynamic power-switching enabled  
Strap options disabled  
LED mode = Speed (when available on package)  
Individual power switching  
Individual over-current sensing  
1
0
1
Internal Default Configuration with the following over-rides  
„
„
„
„
„
Dynamic setting enabled  
Strap options disabled  
LED mode = USB (when available on package)  
Individual power switching  
Individual over-current sensing  
1
1
1
1
0
1
Internal Default Configuration with the following over-rides  
„
„
„
„
Strap options disabled  
LED mode = Speed (when available on package)  
Individual power switching  
Individual over-current sensing  
Internal Default Configuration with the following over-rides  
„ Strap options disabled  
„ LED mode = USB (when available on package)  
„ Ganged port power switching  
„ Ganged over-current sensing  
Note: When the CFG_SEL[2] pin is unavailable, then the logic is internally tied to ‘0’.  
8.1.2.1  
Power Switching Polarity  
When the PRTPWR_POL pin is unavailable (3 and 4 port, 48-pin packages only), the hub only  
supports “active high” port power controllers.  
8.1.3  
VBus Detect  
According to Section 7.2.1 of the USB 2.0 specification, a downstream port can never provide power  
to its D+ or D- pull-up resistors unless the upstream port’s VBUS is in the asserted (powered) state.  
The VBUS_DET pin on the hub monitors the state of the upstream VBUS signal and will not pull-up  
the D+ resistor if VBUS is not active. If VBUS goes from an active to an inactive state (Not Powered),  
the hub will remove power from the D+ pull-up resistor within 10 seconds.  
8.2  
EEPROM Interface  
The SMSC hub can be configured via a 2-wire (I2C) EEPROM (256x8). (Please see Table 8.1, "Hub  
Configuration Options" for specific details on how to enable configuration via an I2C EEPROM).  
The internal state-machine will (when configured for EEPROM support) read the external EEPROM for  
configuration data. The hub will then “attach” to the upstream USB host.  
Note: The hub does not have the capacity to write, or “Program,” an external EEPROM. The hub  
only has the capability to read external EEPROMs. The external eeprom will be read (even if  