USB MultiSwitchTM Hub  
Datasheet  
Chapter 9 Reset  
9.1  
Reset  
There are two different resets that the Hub experiences. One is a hardware reset (via the RESET_N  
pin) and the second is a USB Bus Reset.  
9.1.1  
External Hardware RESET_N  
A valid hardware reset is defined as, assertion of RESET_N for a minimum of 1us after all power  
supplies are within operating range. While reset is asserted, the Hub (and its associated external  
circuitry) consumes less than 500μA of current from the upstream USB power source (300μA for the  
Hub and 200μA for the external circuitry).  
Assertion of RESET_N (external pin) causes the following:  
„
„
„
„
„
„
„
All downstream ports are disabled, and PRTPWR power to downstream devices is removed.  
The PHYs are disabled, and the differential pairs will be in a high-impedance state.  
All transactions immediately terminate; no states are saved.  
All internal registers return to the default state (in most cases, 00(h)).  
The external crystal oscillator is halted.  
The PLL is halted.  
LED indicators are disabled.  
The Hub is “operational” 500μs after RESET_N is negated.  
Once operational, the Hub immediately reads OEM-specific data from the external EEPROM (if the  
SMBus option is not disabled) or the internal ROM.  
SMSC USB2524  
Revision 1.91 (08-22-07)  
DATA4S7HEET  