16-bit High-Performance Single-Chip 10/100 Ethernet Controller with HP Auto-MDIX  
Datasheet  
Chapter 6 Timing Diagrams  
6.1  
Host Interface Timing  
The LAN9217 supports the following host cycles:  
Read Cycles:  
„
„
„
„
PIO Reads (nCS or nRD controlled)  
PIO Burst Reads (nCS or nRD controlled)  
RX Data FIFO Direct PIO Reads (nCS or nRD controlled)  
RX Data FIFO Direct PIO Burst Reads (nCS or nRD controlled)  
Write Cycles:  
„
PIO writes (nCS and nWR controlled)  
TX Data FIFO direct PIO writes (nCS or nWR controlled)  
„
All timing measurements were verified under the following conditions:  
Temperature: ........................................................................................................................0oC to +70°C  
Device VDD:....................................................................................................................+3.30 V +/- 10%  
Load Capacitance: ............................................................................................................................ 25pF  
6.1.1  
Special Restrictions on Back-to-Back Write/Read Cycles  
It is important to note that there are specific restrictions on the timing of back-to-back write-read  
operations. These restrictions concern reading the control registers after any write cycle to the  
LAN9217 device. In many cases there is a required minimum delay between writing to the LAN9217,  
and the subsequent side effect (change in the control register value). For example, when writing to the  
TX Data FIFO, it takes up to 135ns for the level indication to change in the TX_FIFO_INF register.  
In order to prevent the host from reading stale data after a write operation, minimum wait periods must  
be enforced. These periods are specified in Table 6.1, "Read After Write Timing Rules". The host  
processor is required to wait the specified period of time after any write to the LAN9217 before reading  
the resource specified in the table. These wait periods are for read operations that immediately follow  
any write cycle. Note that the required wait period is dependant upon the register being read after the  
write.  
Performing "dummy" reads of the BYTE_TEST register is a convenient way to guarantee that the  
minimum write-to-read timing restriction is met. Table 6.1 also shows the number of dummy reads that  
are required before reading the register indicated. The number of BYTE_TEST reads in this table is  
based on the minimum timing for Tcycle (45ns). For microprocessors with slower busses the number  
of reads may be reduced as long as the total time is equal to, or greater than the time specified in the  
table. Note that dummy reads of the BYTE_TEST register are not required as long as the minimum  
time period is met.  