 浏览型号LAN9210的Datasheet PDF文件第67页浏览型号LAN9210的Datasheet PDF文件第68页浏览型号LAN9210的Datasheet PDF文件第69页浏览型号LAN9210的Datasheet PDF文件第70页浏览型号LAN9210的Datasheet PDF文件第72页浏览型号LAN9210的Datasheet PDF文件第73页浏览型号LAN9210的Datasheet PDF文件第74页浏览型号LAN9210的Datasheet PDF文件第75页  
High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface  
Datasheet  
Table 6.2 Spanning Tree States (continued)  
Port State  
Hardware Action  
Software Action  
11 - Listening  
Received packets on the port are  
discarded.  
The MAC Address Table should be programmed  
with entries that the host CPU needs to receive  
(e.g. the BPDU address). The static and override  
Transmissions to the port are blocked. bits should be set.  
Learning on the port is disabled.  
The host CPU may send packets to the port in this  
state.  
10 - Learning  
Received packets on the port are  
discarded.  
The MAC Address Table should be programmed  
with entries that the host CPU needs to receive  
(e.g. the BPDU address). The static and override  
Transmissions to the port are blocked. bits should be set.  
Learning on the port is enabled.  
The host CPU may send packets to the port in this  
state.  
00 - Forwarding  
Received packets on the port are  
forwarded normally.  
The MAC Address Table should be programmed  
with entries that the host CPU needs to receive  
(e.g. the BPDU address). The static and override  
bits should be set.  
Transmissions to the port are sent  
normally.  
The host CPU may send packets to the port in this  
state.  
Learning on the port is enabled.  
6.4.6  
Ingress Flow Metering and Coloring  
The LAN9312 supports hardware ingress rate limiting by metering packet streams and marking packets  
as either Green, Yellow, or Red according to three traffic parameters: Committed Information Rate  
(CIR), Committed Burst Size (CBS), and Excess Burst Size (EBS). A packet is marked Green if it does  
not exceed the CBS, Yellow if it exceeds to CBS but not the EBS, or Red otherwise.  
Ingress flow metering and coloring is enabled via the Ingress Rate Enable bit in the Switch Engine  
Ingress Rate Configuration Register (SWE_INGRSS_RATE_CFG). Once enabled, each incoming  
packet is classified into a stream. Streams are defined as per port (3 streams), per priority (8 streams),  
or per port & priority (24 streams) as selected via the Rate Mode bits in the Switch Engine Ingress  
Rate Configuration Register (SWE_INGRSS_RATE_CFG). Each stream can have a different CIR  
setting. All streams share common CBS and EBS settings. CIR, CBS, and EBS are programmed via  
the Switch Engine Ingress Rate Command Register (SWE_INGRSS_RATE_CMD) and Switch Engine  
Ingress Rate Write Data Register (SWE_INGRSS_RATE_WR_DATA).  
Each stream is metered according to RFC 2697. At the rate set by the CIR, two token buckets are  
credited per stream. First, the Committed Burst bucket is incremented up to the maximum set by the  
CBS. Once the Committed Burst bucket is full, the Excess Burst bucket is incremented up to the  
maximum set by the EBS. The CIR rate is specified in time per byte. The value programmed is in  
approximately 20 nS per byte increments. Typical values are listed in Table 6.3. When a port is  
receiving at 10Mbps, any setting faster than 39 has the effect of not limiting the rate.  
SMSC LAN9312  
Revision 1.2 (04-08-08)  
DATA7S1HEET