Small Footprint RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support  
Datasheet  
no change in operation or performance due to the event. All pins on the LAN8720 provide +/-5kV HBM  
protection.  
7.1.1.2  
IEC61000-4-2 Performance  
The IEC61000-4-2 ESD specification is an international standard that addresses system-level immunity  
to ESD strikes while the end equipment is operational. In contrast, the HBM ESD tests are performed  
at the device level with the device powered down.  
SMSC contracts with Independent laboratories to test the LAN8720 to IEC61000-4-2 in a working  
system. Reports are available upon request. Please contact your SMSC representative, and request  
information on 3rd party ESD test results. The reports show that systems designed with the LAN8720  
can safely dissipate ±15kV air discharges and ±15kV contact discharges per the IEC61000-4-2  
specification without additional board level protection.  
In addition to defining the ESD tests, IEC 61000-4-2 also categorizes the impact to equipment  
operation when the strike occurs (ESD Result Classification). The LAN8720 maintains an ESD Result  
Classification 1 or 2 when subjected to an IEC 61000-4-2 (level 4) ESD strike.  
Both air discharge and contact discharge test techniques for applying stress conditions are defined by  
the IEC61000-4-2 ESD document.  
AIR DISCHARGE  
To perform this test, a charged electrode is moved close to the system being tested until a spark is  
generated. This test is difficult to reproduce because the discharge is influenced by such factors as  
humidity, the speed of approach of the electrode, and construction of the test equipment.  
CONTACT DISCHARGE  
The uncharged electrode first contacts the pin to prepare this test, and then the probe tip is energized.  
This yields more repeatable results, and is the preferred test method. The independent test laboratories  
contracted by SMSC provide test results for both types of discharge methods.  
7.1.2  
Operating Conditions  
Table 7.3 Recommended Operating Conditions  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
3.6  
UNITS  
COMMENT  
VDD1A, VDD2A  
VDDIO  
To VSS ground  
To VSS ground  
3.0  
1.6  
0.0  
3.3  
3.3  
V
3.6  
V
V
Input Voltage on  
Digital Pins  
VDDIO  
Voltage on Analog I/O  
pins (RXP, RXN)  
0.0  
0
+3.6V  
+85  
V
Ambient Temperature  
TA LAN8720-AEZG  
TA LAN8720i-AEZG  
oC  
oC  
For Extended Commercial  
Temperature  
-40  
+85  
For Industrial Temperature  
7.1.3  
Power Consumption  
7.1.3.1  
Power Consumption Device Only REF_CLK IN Mode  
Power measurements taken over the operating conditions specified. See Section 5.3.5 for a description  
of the power down modes. For more information on REF_CLK IN Mode, see Section 4.7.1.  
SMSC LAN8720/LAN8720i  
Revision 1.0 (05-28-09)  
DATA6S7HEET