OPERATIONAL DESCRIPTION
MAXIMUM GUARANTEED RATINGS*
Operating Temperature Range.....................................................................................................0oC to +70oC
Storage Temperature Range..................................................................................................... -55o to +150oC
Lead Temperature Range (soldering, 10 seconds)...............................................................................+325oC
Positive Voltage on any pin, with respect to Ground ...........................................................................Vcc+0.3V
Negative Voltage on any pin, except VDD, with respect to Ground........................................................... -0.3V
*Stresses above those listed above could cause permanent damage to the device. This is a stress rating
only and functional operation of the device at any other condition above those indicated in the operation
sections of this specification is not implied.
Note: When powering this device from laboratory or system power supplies, it is important that the
Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit
voltage spikes on their outputs when the AC power is switched on or off. In addition, voltage transients on
the AC power line may appear on the DC output. If this possibility exists, it is suggested that a clamp circuit
be used.
(T = 0oC to 70oC, VCC2 = +5.0 V ± 5%, VDD = -5.0V ± 5%)
DC ELECTRICAL CHARACTERISTICS
PARAMETER
Low Input Voltage
A
SYMBOL
MIN
TYP
MAX
UNITS
COMMENTS
VIL
0.8
V
IIL = -0.8 mA
High Input Voltage
VIH
VR
2.0
V
IIH = +0.2 mA
Received Signal Amplitude
6.0
3.0
Vp-p
Vo-p
Low Output Voltage
High Output Voltage
Transformer Output
VOL
VOH
VT
0.4
V
One TTL Load
One TTL Load
2.4
V
16
8
20
10
Vp-p
VO-p
Zchr cable = 120 or
Ω
93
Ω
Cable Noise Amplitude
VCC Supply Current
VC
ICC
4
Vp-p
mA
190
180
285
VDD Supply Current
IDD
270
mA
nS
Pulse Width, nPulse 1, n2
PW
100
Shorting the transformer output may cause permanent damage to the device.