CRC bytes, and at the end of the sector,  
terminate the Read Data Command.  
DATA TRANSFER COMMANDS  
All of the Read Data, Write Data and Verify type  
commands use the same parameter bytes and  
return the same results information, the only  
difference being the coding of bits 0-4 in the first  
byte.  
N determines the number of bytes per sector  
(see Table 22 below). If N is set to zero, the  
sector size is set to 128. The DTL value  
determines the number of bytes to be  
transferred. If DTL is less than 128, the FDC  
transfers the specified number of bytes to the  
host. For reads, it continues to read the entire  
128-byte sector and checks for CRC errors. For  
writes, it completes the 128-byte sector by filling  
in zeros. If N is not set to 00 Hex, DTL should  
be set to FF Hex and has no impact on the  
number of bytes transferred.  
An implied seek will be executed if the feature  
was enabled by the Configure command. This  
seek is completely transparent to the user. The  
Drive Busy bit for the drive will go active in the  
Main Status Register during the seek portion of  
the command. If the seek portion fails, it is  
reflected in the results status normally returned  
for  
a
Read/Write Data command. Status  
Register 0 (ST0) would contain the error code  
and C would contain the cylinder on which the  
seek failed.  
Table 22 - Sector Sizes  
N
SECTOR SIZE  
00  
01  
02  
03  
..  
128 bytes  
256 bytes  
512 bytes  
1024 bytes  
...  
Read Data  
A set of nine (9) bytes is required to place the  
FDC in the Read Data Mode. After the Read  
Data command has been issued, the FDC loads  
the head (if it is in the unloaded state), waits the  
specified head settling time (defined in the  
Specify command), and begins reading ID  
Address Marks and ID fields. When the sector  
address read off the diskette matches with the  
sector address specified in the command, the  
FDC reads the sector's data field and transfers  
the data to the FIFO.  
07  
16 Kbytes  
The amount of data which can be handled with  
a single command to the FDC depends upon  
MT (multi-track) and N (number of bytes/sector).  
The Multi-Track function (MT) allows the FDC to  
read data from both sides of the diskette. For a  
particular cylinder, data will be transferred  
starting at Sector 1, Side 0 and completing the  
last sector of the same track at Side 1.  
After completion of the read operation from the  
current sector, the sector address is  
incremented by one and the data from the next  
logical sector is read and output via the FIFO.  
This continuous read function is called "Multi-  
Sector Read Operation". Upon receipt of TC, or  
an implied TC (FIFO overrun/underrun), the  
FDC stops sending data but will continue to  
read data from the current sector, check the  
If the host terminates a read or write operation  
in the FDC, the ID information in the result  
phase is dependent upon the state of the MT bit  
and EOT byte. Refer to Table 23.  
55  