OPERATIONAL DESCRIPTION
MAXIMUM GUARANTEED RATINGS*
Operating Temperature Range......................................................................................... 0oC to +70oC
Storage Temperature Range..........................................................................................-55o to +150oC
Lead Temperature Range (soldering, 10 seconds) ....................................................................+325oC
Positive Voltage on any pin, with respect to Ground................................................................Vcc+0.3V
Negative Voltage on any pin, with respect to Ground.................................................................... -0.3V
Maximum Vcc................................................................................................................................. +7V
*Stresses above those listed above could cause permanent damage to the device. This is a stress
rating only and functional operation of the device at any other condition above those indicated in the
operation sections of this specification is not implied.
Note: When powering this device from laboratory or system power supplies, it is important that the
Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit
voltage spikes on their outputs when the AC power is switched on or off. In addition, voltage
transients on the AC power line may appear on the DC output. If this possibility exists, it is suggested
that a clamp circuit be used.
DC ELECTRICAL CHARACTERISTICS
(TA = 0°C - 70°C, Vcc = +5 V ± 10%)
PARAMETER
SYMBOL
MIN
2.0
TYP
MAX
UNITS
COMMENTS
I Type Input Buffer
VILI
VIHI
0.8
V
V
TTL Levels
Low Input Level
High Input Level
IS Type Input Buffer
VILIS
VIHIS
VHYS
0.8
0.4
V
V
Schmitt Trigger
Schmitt Trigger
Low Input Level
High Input Level
2.2
250
mV
Schmitt Trigger Hysteresis
ICLK Input Buffer
VILCK
VIHCK
V
V
Low Input Level
2.2
High Input Level
ICLK2 Input Buffer
500
mV
V P - P
Input Level
146