PRETRK - Pre-Compensation Start Track Number.  
Programmable from track 0 to 255. Defaults to track 0. A  
"00" selects track 0; "FF" selects track 255.  
Seek command is 255 (D).  
The internal register, PCN, will overflow as the cylinder  
number crosses track 255 and will contain 39 (D). The  
resulting PCN value is thus (RCN + PCN) mod 256.  
Functionally, the FDC starts counting from 0 again as the  
track number goes above 255 (D). It is the user's  
Version  
The Version command checks to see if the controller is  
an enhanced type or the older type (765A). A value of 90  
H is returned as the result byte.  
responsibility  
to  
compensate  
FDC  
functions  
(precompensation track number) when accessing tracks  
greater than 255. The FDC does not keep track that it is  
working in an "extended track area" (greater than 255).  
Any command issued will use the current PCN value  
except for the Recalibrate command, which only looks for  
the TRACK0 signal. Recalibrate will return an error if the  
head is farther than 79 due to its limitation of issuing a  
maximum of 80 step pulses. The user simply needs to  
Relative Seek  
The command is coded the same as for Seek, except for  
the MSB of the first byte and the DIR bit.  
DIR  
Head Step Direction Control  
issue a second Recalibrate command.  
The Seek  
DIR  
ACTION  
command and implied seeks will function correctly within  
the 44 (D) track (299-255) area of the "extended track  
area". It is the user's responsibility not to issue a new  
track position that will exceed the maximum track that is  
present in the extended area.  
0
1
Step Head Out  
Step Head In  
RCN Relative Cylinder Number that determines how  
many tracks to step the head in or out from the  
current track number.  
To return to the standard floppy range (0-255) of tracks, a  
Relative Seek should be issued to cross the track 255  
boundary.  
The Relative Seek command differs from the Seek  
command in that it steps the head the absolute number of  
tracks specified in the command instead of making a  
comparison against an internal register. The Seek  
command is good for drives that support a maximum of  
256 tracks. Relative Seeks cannot be overlapped with  
other Relative Seeks. Only one Relative Seek can be  
active at a time. Relative Seeks may be overlapped with  
Seeks and Recalibrates. Bit 4 of Status Register 0 (EC)  
will be set if Relative Seek attempts to step outward  
beyond Track 0.  
A Relative Seek can be used instead of the normal Seek,  
but the host is required to calculate the difference  
between the current head location and the new (target)  
head location. This may require the host to issue a Read  
ID command to ensure that the head is physically on the  
track that software assumes it to be. Different FDC  
commands will return different cylinder results which may  
be difficult to keep track of with software without the Read  
ID command.  
Perpendicular Mode  
As an example, assume that a floppy drive has 300  
useable tracks. The host needs to read track 300 and the  
head is on any track (0-255). If a Seek command is  
issued, the head will stop at track 255. If a Relative Seek  
command is issued, the FDC will move the head the  
specified number of tracks, regardless of the internal  
cylinder position register (but will increment the register).  
If the head was on track 40 (d), the maximum track that  
the FDC could position the head on using Relative Seek  
will be 295 (D), the initial track + 255 (D). The maximum  
count that the head can be moved with a single Relative  
The Perpendicular Mode command should be issued  
prior to executing Read/Write/Format commands that  
access  
a disk drive with perpendicular recording  
capability. With this command, the length of the Gap2  
field and VCO enable timing can be altered to  
accommodate the unique requirements of these drives.  
Table 31 describes the effects of the WGATE and GAP  
bits for the Perpendicular Mode command. Upon a reset,  
the FDC will default to the conventional mode (WGATE =  
0, GAP = 0).  