AUTO POWER MANAGEMENT
Power management capabilities are provided for the
An internal timer is initiated as soon as the auto
powerdown command is enabled. The part is then
powered down when all the conditions are met. During
the countdown of the powerdown timer, any operation of
read MSR or read/write data (FIFO) will reinitiate the
timer.
following logical devices: floppy disk, UART 1, UART 2
and the parallel port. For each logical device, two types
of power management are provided; direct powerdown
and auto powerdown.
Direct powerdown is controlled by the powerdown bits in
the configuration registers. One bit is provided for each
logical device. Auto Powerdown can be enabled for each
logical device by setting the Auto Powerdown Enable bit
Disabling the auto powerdown mode cancels the timer
and holds the FDC37C669 out of auto powerdown.
in the configluration registers.
In addition, a chip
DSR From Powerdown
powerdown has been provided by using the
POWERGOOD pin. Refer to the description of the
POWERGOOD pin for more information.
If DSR powerdown is used when the part is in auto
powerdown, the DSR powerdown will override the auto
powerdown. However, when the part is awakened from
DSR powerdown, the auto powerdown will once again
become effective.
FDC Power Management
Direct power management is controlled by bit 3 of
Configuration Register 0(CR0). Refer to CR0 bit 3 for
more information.
Wake Up From Auto Powerdown
If the part enters the powerdown state through the auto
powerdown mode, then the part can be awakened by
reset or by appropriate access to certain registers.
Auto Power Management is enabled by CR7 bit 7. When
set, this bit allows FDC to enter powerdown when all of
the following conditions have been met:
If a hardware or software reset is used then the part will
go through the normal reset sequence. If the access is
through the selected registers, then the FDC37C669
resumes operation as though it was never in powerdown.
Besides activating the RESET pin or one of the software
reset bits in the DOR or DSR, the following register
accesses will wake up the part:
1. Enabling any one of the motor enable bits in the
DOR register (reading the DOR does not awaken the
part).
1. The motor enable pins of register DOR (3F2H/372H)
are inactive (zero).
2. The part must be idle; MSR=80H and INT = 0 (INT
may be high even if MSR = 80H due to polling
interrupts).
3. The internal head unload timer must have expired.
4. The Auto powerdown timer (10msec) must have
timed out.
2. A read from the MSR register.
3. A read or write to the Data register.