OPERATION  
Mode Switching/Software Control  
Set autoFd = 0, causing the nAutoFd signal  
to default to the deasserted state.  
Set mode = 011 (ECP Mode)  
Software will execute P1284 negotiation and all  
operation prior to a data transfer phase under  
programmed I/O control (mode 000 or 001).  
Hardware provides an automatic control line  
handshake, moving data between the FIFO and  
the ECP port only in the data transfer phase  
(modes 011 or 010).  
ECP address/RLE bytes or data bytes may be  
sent automatically by writing the ecpAFifo or  
ecpDFifo respectively.  
Note that all FIFO data transfers are byte wide and  
byte aligned.  
Address/RLE transfers are  
byte-wide and only allowed in the forward  
direction.  
Setting the mode to 011 or 010 will cause the  
hardware to initiate data transfer.  
The host may switch directions by first switching to  
mode = 001, negotiating for the forward or reverse  
channel, setting direction to 1 or 0, then setting  
mode = 011. When direction is 1 the hardware  
shall handshake for each ECP read data byte and  
attempt to fill the FIFO. Bytes may then be read  
from the ecpDFifo as long as it is not empty.  
If the port is in mode 000 or 001 it may switch to  
any other mode. If the port is not in mode 000 or  
001 it can only be switched into mode 000 or 001.  
The direction can only be changed in mode 001.  
Once in an extended forward mode the software  
should wait for the FIFO to be empty before  
switching back to mode 000 or 001. In this case  
all control signals will be deasserted before the  
mode switch. In an ecp reverse mode the software  
waits for all the data to be read from the FIFO  
before changing back to mode 000 or 001. Since  
the automatic hardware ecp reverse handshake  
only cares about the state of the FIFO it may have  
acquired extra data which will be discarded. It may  
in fact be in the middle of a transfer when the  
mode is changed back to 000 or 001. In this case  
the port will deassert nAutoFd independent of the  
state of the transfer. The design shall not cause  
glitches on the handshake signals if the software  
meets the constraints above.  
ECP transfers may also be accomplished (albeit  
slowly) by handshaking individual bytes under  
program control in mode = 001, or 000.  
Termination from ECP Mode  
Termination from ECP Mode is similar to the  
termination from Nibble/Byte Modes. The host is  
permitted to terminate from ECP Mode only in  
specific well-defined states. The termination can  
only be executed while the bus is in the forward  
direction. To terminate while the channel is in the  
reverse direction, it must first be transitioned into  
the forward direction.  
ECP Operation  
Prior to ECP operation the Host must negotiate on  
the parallel port to determine if the peripheral  
supports the ECP protocol. This is a somewhat  
complex negotiation carried out under program  
control in mode 000.  
After negotiation, it is necessary to initialize some  
of the port bits. The following are required:  
Set Direction = 0, enabling the drivers.  
Set strobe = 0, causing the nStrobe signal to  
default to the deasserted state.  