欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37B776 参数 Datasheet PDF下载

FDC37B776图片预览
型号: FDC37B776
PDF下载: 下载PDF文件 查看货源
内容描述: 增强的超级I / O控制器带唤醒特点 [ENHANCED SUPER I/O CONTROLLER WITH WAKE UP FEATURES]
分类和应用: 控制器
文件页数/大小: 196 页 / 566 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37B776的Datasheet PDF文件第93页浏览型号FDC37B776的Datasheet PDF文件第94页浏览型号FDC37B776的Datasheet PDF文件第95页浏览型号FDC37B776的Datasheet PDF文件第96页浏览型号FDC37B776的Datasheet PDF文件第98页浏览型号FDC37B776的Datasheet PDF文件第99页浏览型号FDC37B776的Datasheet PDF文件第100页浏览型号FDC37B776的Datasheet PDF文件第101页  
Table 39A - Extended Control Register  
MODE  
R/W  
000: Standard Parallel Port Mode . In this mode the FIFO is reset and common collector drivers  
are used on the control lines (nStrobe, nAutoFd, nInit and nSelectIn). Setting the direction  
bit will not tri-state the output drivers in this mode.  
001: PS/2 Parallel Port Mode. Same as above except that direction may be used to tri-state the  
data lines and reading the data register returns the value on the data lines and not the  
value in the data register. All drivers have active pull-ups (push-pull).  
010: Parallel Port FIFO Mode. This is the same as 000 except that bytes are written or DMAed to  
the FIFO. FIFO data is automatically transmitted using the standard parallel port protocol.  
Note that this mode is only useful when direction is 0. All drivers have active pull-ups  
(push-pull).  
011: ECP Parallel Port Mode. In the forward direction (direction is 0) bytes placed into the  
ecpDFifo and bytes written to the ecpAFifo are placed in a single FIFO and transmitted  
automatically to the peripheral using ECP Protocol. In the reverse direction (direction is 1)  
bytes are moved from the ECP parallel port and packed into bytes in the ecpDFifo. All  
drivers have active pull-ups (push-pull).  
100: Selects EPP Mode: In this mode, EPP is selected if the EPP supported option is selected in  
configuration register L3-CRF0. All drivers have active pull-ups (push-pull).  
101: Reserved  
110: Test Mode. In this mode the FIFO may be written and read, but the data will not be  
transmitted on the parallel port. All drivers have active pull-ups (push-pull).  
111: Configuration Mode. In this mode the confgA, confgB registers are accessible at 0x400 and  
0x401. All drivers have active pull-ups (push-pull).  
Table 39B  
CONFIG REG B  
Table 39C  
CONFIG REG B  
IRQ SELECTED  
BITS 5:3  
DMA SELECTED  
BITS 2:0  
15  
110  
3
011  
14  
101  
100  
011  
010  
001  
111  
000  
2
1
010  
001  
000  
11  
10  
All Others  
9
7
5
All Others  
97  
 复制成功!