Framing Error (FE). Bit 3 indicates that the  
received character did not have a valid stop bit.  
Bit 3 is set to a logic "1" whenever the stop bit  
following the last data bit or parity bit is detected  
as a zero bit (Spacing level). The FE is reset to a  
logic "0" whenever the Line Status Register is  
read. In the FIFO mode this error is associated  
with the particular character in the FIFO it applies  
to. This error is indicated when the associated  
character is at the top of the FIFO. The Serial Port  
will try to resynchronize after a framing error. To  
do this, it assumes that the framing error was due  
to the next start bit, so it samples this 'start' bit  
twice and then takes in the 'data'.  
Bit 5  
Transmitter Holding Register Empty (THRE). Bit 5  
indicates that the Serial Port is ready to accept a  
new character for transmission. In addition, this bit  
causes the Serial Port to issue an interrupt when  
the Transmitter Holding Register interrupt enable  
is set high. The THRE bit is set to a logic "1" when  
a character is transferred from the Transmitter  
Holding Register into the Transmitter Shift  
Register. The bit is reset to logic "0" whenever the  
CPU loads the Transmitter Holding Register. In  
the FIFO mode this bit is set when the XMIT FIFO  
is empty, it is cleared when at least 1 byte is  
written to the XMIT FIFO. Bit 5 is a read only bit.  
Bit 6  
Bit 4  
Break Interrupt (BI). Bit 4 is set to a logic "1"  
whenever the received data input is held in the  
Spacing state (logic "0") for longer than a full word  
transmission time (that is, the total time of the start  
bit + data bits + parity bits + stop bits). The BI is  
reset after the CPU reads the contents of the Line  
Status Register. In the FIFO mode this error is  
associated with the particular character in the  
FIFO it applies to. This error is indicated when the  
associated character is at the top of the FIFO.  
When break occurs only one zero character is  
loaded into the FIFO. Restarting after a break is  
received, requires the serial data (RXD) to be logic  
"1" for at least 1/2 bit time.  
Transmitter Empty (TEMT). Bit 6 is set to a logic  
"1" whenever the Transmitter Holding Register  
(THR) and Transmitter Shift Register (TSR) are  
both empty. It is reset to logic "0" whenever either  
the THR or TSR contains a data character. Bit 6  
is a read only bit. In the FIFO mode this bit is set  
whenever the THR and TSR are both empty,  
Bit 7  
This bit is permanently set to logic "0" in the 450  
mode. In the FIFO mode, this bit is set to a logic  
"1" when there is at least one parity error, framing  
error or break indication in the FIFO. This bit is  
cleared when the LSR is read if there are no  
subsequent errors in the FIFO.  
Note: Bits 1 through 4 are the error conditions that  
MODEM STATUS REGISTER (MSR)  
Address Offset = 6H, DLAB = X, READ/WRITE  
produce  
a
Receiver Line Status Interrupt  
whenever any of the corresponding conditions are  
detected and the interrupt is enabled.  
This 8 bit register provides the current state of the  
control lines from the MODEM (or peripheral  
device).  
In addition to this current state  
information, four bits of the MODEM Status  
Register (MSR) provide change information.  
These bits are set to logic "1" whenever a control  
input from the MODEM changes state. They are  
reset to logic "0" whenever the MODEM Status  
Register is read.  