 浏览型号FDC37B72X_07的Datasheet PDF文件第61页浏览型号FDC37B72X_07的Datasheet PDF文件第62页浏览型号FDC37B72X_07的Datasheet PDF文件第63页浏览型号FDC37B72X_07的Datasheet PDF文件第64页浏览型号FDC37B72X_07的Datasheet PDF文件第66页浏览型号FDC37B72X_07的Datasheet PDF文件第67页浏览型号FDC37B72X_07的Datasheet PDF文件第68页浏览型号FDC37B72X_07的Datasheet PDF文件第69页  
above 255 (D). It is the user's responsibility to  
compensate FDC functions (precompensation  
track number) when accessing tracks greater than  
255. The FDC does not keep track that it is  
working in an "extended track area" (greater than  
255). Any command issued will use the current  
PCN value except for the Recalibrate command,  
which only looks for the TRACK0 signal.  
Recalibrate will return an error if the head is farther  
than 79 due to its limitation of issuing a maximum  
of 80 step pulses. The user simply needs to issue  
Relative Seek  
The command is coded the same as for Seek,  
except for the MSB of the first byte and the DIR  
bit.  
DIR  
0
1
ACTION  
Step Head Out  
Step Head In  
a second Recalibrate command.  
The Seek  
DIR  
Head Step Direction Control  
command and implied seeks will function correctly  
within the 44 (D) track (299-255) area of the  
"extended track area". It is the user's responsibility  
not to issue a new track position that will exceed  
the maximum track that is present in the extended  
area.  
RCN Relative Cylinder Number that determines  
how many tracks to step the head in or out  
from the current track number.  
The Relative Seek command differs from the Seek  
command in that it steps the head the absolute  
number of tracks specified in the command  
instead of making a comparison against an  
internal register. The Seek command is good for  
drives that support a maximum of 256 tracks.  
Relative Seeks cannot be overlapped with other  
Relative Seeks. Only one Relative Seek can be  
To return to the standard floppy range (0-255) of  
tracks, a Relative Seek should be issued to cross  
the track 255 boundary.  
A Relative Seek can be used instead of the normal  
Seek, but the host is required to calculate the  
difference between the current head location and  
the new (target) head location. This may require  
the host to issue a Read ID command to ensure  
that the head is physically on the track that  
active at  
a time. Relative Seeks may be  
overlapped with Seeks and Recalibrates. Bit 4 of  
Status Register 0 (EC) will be set if Relative Seek  
attempts to step outward beyond Track 0.  
software assumes it to be.  
Different FDC  
commands will return different cylinder results  
which may be difficult to keep track of with  
software without the Read ID command.  
Perpendicular Mode  
As an example, assume that a floppy drive has  
300 useable tracks. The host needs to read track  
300 and the head is on any track (0-255). If a Seek  
command is issued, the head will stop at track  
255. If a Relative Seek command is issued, the  
FDC will move the head the specified number of  
tracks, regardless of the internal cylinder position  
register (but will increment the register). If the head  
was on track 40 (d), the maximum track that the  
FDC could position the head on using Relative  
Seek will be 295 (D), the initial track + 255 (D).  
The maximum count that the head can be moved  
with a single Relative Seek command is 255 (D).  
The Perpendicular Mode command should be  
issued prior to executing Read/Write/Format  
commands that access  
perpendicular recording capability.  
a
disk drive with  
With this  
command, the length of the Gap2 field and VCO  
enable timing can be altered to accommodate the  
unique requirements of these drives. Table 28  
describes the effects of the WGATE and GAP bits  
for the Perpendicular Mode command. Upon a  
reset, the FDC will default to the conventional  
mode (WGATE = 0, GAP = 0).  
The internal register, PCN, will overflow as the  
cylinder number crosses track 255 and will contain  
39 (D). The resulting PCN value is thus (RCN +  
PCN) mod 256. Functionally, the FDC starts  
counting from 0 again as the track number goes  
Selection of the 500 Kbps and  
1
Mbps  
perpendicular modes is independent of the actual  
65  