Dual RPM-Based PWM Fan Controller with Hardware Thermal Shutdown  
Datasheet  
4.3  
Read Byte  
The Read Byte protocol is used to read one byte of data from the registers as shown in Table 4.3.  
Table 4.3 Read Byte Protocol  
START  
SLAVE  
ADDRESS  
WR  
ACK  
Register  
Address  
ACK  
START  
Slave  
Address  
RD  
ACK  
Register  
Data  
NACK  
STOP  
0 -> 1  
0101_111  
0
0
XXh  
0
0 -> 1  
0101_111  
1
0
XXh  
1
1 -> 0  
4.4  
Send Byte  
The Send Byte protocol is used to set the internal address register pointer to the correct address  
location. No data is transferred during the Send Byte protocol as shown in Table 4.4.  
Table 4.4 Send Byte Protocol  
SLAVE  
ADDRESS  
REGISTER  
ADDRESS  
START  
0 -> 1  
WR  
ACK  
ACK  
STOP  
0101_111  
0
0
XXh  
0
1 -> 0  
4.5  
Receive Byte  
The Receive Byte protocol is used to read data from a register when the internal register address  
pointer is known to be at the right location (e.g. set via Send Byte). This is used for consecutive reads  
of the same register as shown in Table 4.5.  
Table 4.5 Receive Byte Protocol  
SLAVE  
START  
ADDRESS  
RD  
ACK  
REGISTER DATA  
NACK  
STOP  
0 -> 1  
0101_111  
1
0
XXh  
1
1 -> 0  
4.6  
Alert Response Address  
The ALERT# output can be used as a processor interrupt or as an SMBus Alert when configured to  
operate as an interrupt.  
When it detects that the ALERT# pin is asserted, the host will send the Alert Response Address (ARA)  
to the general address of 0001_100xb. All devices with active interrupts will respond with their client  
address as shown in Table 4.6.  
Table 4.6 Alert Response Address Protocol  
ALERT  
RESPONSE  
ADDRESS  
DEVICE  
ADDRESS  
START  
RD  
ACK  
NACK  
STOP  
0 -> 1  
0001_100  
1
0
0101_111  
1
1 -> 0  
SMSC EMC2104  
Revision 1.74 (05-08-08)  
DATA1S9HEET