RPM-Based Fan Controller with HW Thermal Shutdown  
Datasheet  
A.2  
Example #2  
This example uses the RPM based Fan Speed Control Algorithm. The Spin Level (used by the Spin  
Up Routine) should be changed to 50% drive for a total Spin Time of 1 second. For all other RPM  
configuration settings, the default conditions are used.  
For control inputs, it uses the External Diode 1 channel normally, the External Diode 2 channel  
normally, and both Pushed Temperature registers in DTS format. The configuration is set as shown in  
Table A.5 while Table A.6 shows how the table is loaded.  
Note that when using DTS data, the USE_DTS_F1 and / or USE_DTS_F2 bits should be set. The  
Pushed Temperature Registers are loaded with the normal DTS values as received by the processor.  
When the DTS value is used by the Look Up Table, the value that is stored in the Pushed Temperature  
Register is subtracted from a fixed temperature of 100°C. This resultant value is then compared  
against the Look Up Table thresholds normally. When programming the Look Up Table, it is necessary  
to take this translation into account or else incorrect settings may be selected.  
Table A.5 Look Up Table Example #2 Configuration  
ADDR  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
SETTING  
EN_  
ALGO  
Fan 1  
Configuration  
1
RANGE[1:0]  
EDGES[1:0]  
UPDATE[2:0]  
1
42h  
46h  
50h  
CBh  
1
1
0
0
0
1
0
0
1
DRIVE_FAIL_CNT1 NOKICK  
SPINUP_TIME  
[1:0]  
Fan 1 Spin  
Up  
Configuration  
SPIN_LVL[2:0]  
1
[1:0]  
1
0Ah  
E5h  
0
0
0
1
0
0
USE_DT  
S_F1  
USE_D  
TS_F2  
LUT_LO  
CK  
RPM /  
PWM  
TEMP3  
_CFG  
TEMP  
3_CFG  
-
LUT 1  
Configuration  
1
1
1
0
0
1
1
Table A.6 Fan Speed Control Table Example #2  
EXTERNAL  
EXTERNAL  
FAN  
SPEED  
STEP #  
DIODE 1  
TEMPERATURE  
(CPU)  
DIODE 2  
TEMPERATURE  
(GPU)  
PUSHED  
TEMPERATURE  
SETTING (DTS1)  
PUSHED  
TEMPERATURE  
SETTING (DTS2)  
TACH  
TARGET  
3Dh  
(1007 RPM)  
1
2
3
4
5
6
35oC  
40oC  
50oC  
60oC  
70oC  
80oC  
65oC  
75oC  
85oC  
90oC  
95oC  
100oC  
50oC  
55oC  
60oC  
65oC  
70oC  
75oC  
40oC  
45oC  
50oC  
55oC  
60oC  
65oC  
1Eh  
(2048 RPM)  
14h  
(3072 RPM)  
0Fh  
(4096 RPM)  
0Ch  
(5120 RPM)  
0Ah  
(6144 RPM)  
Revision 0.85 (01-29-08)  
SMSC EMC2103  
DATA7S8HEET