RPM-Based Fan Controller with HW Thermal Shutdown  
Datasheet  
5.2  
Fan Control Modes of Operation  
The EMC2103 has four modes of operation for the fan driver. Each mode uses Ramp Rate control and  
the Spin Up Routine  
1. PWM Setting Mode - in this mode of operation, the user directly controls the PWM duty cycle  
setting. Updating the Fan Driver Setting Register (see Section 6.20) will instantly update the fan  
drive.  
„ This is the default mode. The PWM Setting Mode is enabled by clearing both the EN_ALGO  
bit in the Fan Configuration Register (see Section 6.22) and the LUT_LOCK bit in the Look  
Up Table Configuration Register (see Section 6.32).  
„ Whenever the PWM Setting Mode is enabled the current drive will be changed to what was  
last written into the Fan Driver Setting Register.  
2. Fan Speed Control Mode (FSC) - in this mode of operation, the user determines a fan speed and  
the drive setting is automatically updated to achieve this target speed.  
„ This mode is enabled by clearing the LUT_LOCK bit in the Look Up Table (LUT)  
Configuration Register and setting the EN_ALGO bit in the Fan Configuration Register.  
3. Using the Look Up Table with Fan Drive Settings (PWM Setting w/ LUT Mode) - In this mode of  
operation, the user programs the Look Up Table with PWM duty cycle settings and corresponding  
temperature thresholds. The fan drive is set based on the measured temperatures and the  
corresponding drive settings.  
„ This mode is enabled by programming the Look Up Table then setting the LUT_LOCK bit  
while the RPM / PWM bit is set to a ‘1’ (see Section 6.32)  
4. Using the Look Up Table with Fan Speed Control algorithm (FSC w/ LUT Mode)- In this mode of  
operation, the user programs the Look Up Table with fan speed target values and corresponding  
temperature thresholds. The TACH Target Register will be set based on the measured  
temperatures and the corresponding target settings. The PWM drive settings will be determined  
automatically based on the RPM based Fan Speed Control Algorithm  
„ This mode is enabled by programming the Look Up Table then setting the LUT_LOCK bit  
while the RPM / PWM bit is set to ‘0’ (see Section 6.32).  
Table 5.3 Fan Controls Active for Operating Mode  
DIRECT PWM  
SETTING MODE  
DIRECT PWM SETTING W/  
LUT MODE  
FSC MODE  
FSC W/ LUT MODE  
Fan Driver Setting (read  
/ write)  
Fan Driver Setting (read  
only)  
Fan Driver Setting (read only) Fan Driver Setting (read  
only)  
EDGES[1:0]  
EDGES[1:0]  
(Fan Configuration)  
EDGES[1:0]  
EDGES[1:0]  
-
RANGE[1:0]  
(Fan Configuration)  
-
RANGE[1:0]  
(Fan Configuration)  
UPDATE[2:0]  
(Fan Configuration)  
UPDATE[2:0]  
(Fan Configuration)  
UPDATE[2:0]  
(Fan Configuration)  
UPDATE[2:0]  
(Fan Configuration)  
LEVEL  
(Spin Up Configuration)  
LEVEL  
(Spin Up Configuration)  
LEVEL  
(Spin Up Configuration)  
LEVEL  
(Spin Up Configuration)  
SPINUP_TIME[1:0]  
(Spin Up Configuration)  
SPINUP_TIME[1:0]  
(Spin Up Configuration)  
SPINUP_TIME[1:0]  
(Spin Up Configuration)  
SPINUP_TIME[1:0]  
(Spin Up Configuration)  
Fan Step  
-
Fan Step  
Fan Step  
Fan Step  
Fan Minimum Drive  
Fan Minimum Drive  
Revision 0.85 (01-29-08)  
SMSC EMC2103  
DATA2S4HEET