 浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第46页浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第47页浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第48页浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第49页浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第50页浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第51页浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第52页浏览型号EMC1701-1-KP-TR的Datasheet PDF文件第54页  
High-Side Current-Sense and Internal 1°C Temperature Monitor  
Datasheet  
Chapter 7 Datasheet Revision History  
Table 7.1 Customer Revision History  
REVISION LEVEL & DATE  
SECTION/FIGURE/ENTRY  
CORRECTION  
Rev. 1.2 (09-27-10)  
Table 2.1, "Absolute  
Maximum Ratings"  
Added spec for voltage between SENSE pins.  
Table 2.2, "Electrical  
Specifications"  
Updated all electrical specs for current sense  
measurement, supply current, and peak detector.  
Electrical Specifications  
APPLICATION NOTE:  
Added note: The EMC1701 is trimmed at the  
80mV range for best accuracy.  
Rev. 1.1 (06-16-10)  
System Diagram  
Updated.  
Section 5.12, "High Limit  
Status Register" and Section  
5.13, "Low Limit Status  
Register"  
ALERT# pin won’t be set if masked.  
Table 5.25, "Current  
Sensing Range (Full Scale  
Range) Settings"  
Changed title from Current Sensing Range to  
Current Sensing Range (Full Scale Range)  
Settings.  
Table 2.1, "Absolute  
Maximum Ratings"  
Upper limit of Operating Ambient Temperature  
Range changed from 125°C to 85°C.  
Table 2.2, "Electrical  
Specifications"  
TA upper limit changed from 125°C to 85°C.  
Bus voltage symbol changed from VSOURCE to  
VBUS  
.
IDD at 4 conversions/second with dynamic  
averaging enabled changed from 0.95 typ and  
1.375 max to 0.9 typ and 1.3 max.  
IDD at 4 conversions/second with dynamic  
averaging disabled changed from 0.80 typ to 0.8  
typ.  
IDD at 1 conversion/second with dynamic  
averaging disabled changed from 650 typ and 1  
max to 0.7 typ and 1.0 max.  
VSENSE Full Scale Sense Range values changed  
from 0 min and +/- max values to - min values and  
+ max values; conditions changed.  
Total Unadjusted VSENSE Measurement Error  
(VSENSE_TUE) renamed VSENSE Measurement  
Error (VSENSE_ERR); typ value at 20-80mV FSR  
changed from 0.8 to +/-0.5 and max changed from  
+/-1.5 to +/-1; typ value at 10mV FSR changed  
from 0.2 to +/-0.8 and max changed from +/-2 to  
+/-1.5.  
VSENSE_OFF condition added.  
VSENSE Measurement Gain Error has new symbol  
VSENSE_GN; added typ +/-0.2 and changed max  
from 0.5 to +/-0.5.  
VTH_ERR changed from +/-20 to +/-2.  
VSOURCE_ERR changed conditions; typ changed  
from 0.05 to +/-0.2 and max changed from 1 to +/-  
0.5.  
Added Power Ratio Measurement specs.  
Data hold time changed from 0.6 min and 6 max  
to 0 min and no max.  
Section 5.27, "Revision  
Register"  
Functional revision C changed default from 81h to  
82h.  
SMSC EMC1701  
Revision 1.2 (09-27-10)  
DATA5S3HEET