欢迎访问ic37.com |
会员登录 免费注册
发布采购

EMC1414-1-AIZL-TR 参数 Datasheet PDF下载

EMC1414-1-AIZL-TR图片预览
型号: EMC1414-1-AIZL-TR
PDF下载: 下载PDF文件 查看货源
内容描述: 多通道1温度传感器,带有beta补偿 [Multiple Channel 1 Temperature Sensors with Beta Compensation]
分类和应用: 传感器温度传感器
文件页数/大小: 52 页 / 897 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第27页浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第28页浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第29页浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第30页浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第32页浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第33页浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第34页浏览型号EMC1414-1-AIZL-TR的Datasheet PDF文件第35页  
Multiple Channel 1°C Temperature Sensors with Beta Compensation  
Datasheet  
Bit 4 - RECD1 - Disables the Resistance Error Correction (REC) for External Diode 1.  
„
„
‘0’ (default) - REC is enabled for External Diode 1.  
‘1’ - REC is disabled for External Diode 1.  
Bit 3 - RECD2 - Disables the Resistance Error Correction (REC) for External Diode 2 and External  
Diode 3.  
„
„
‘0’ (default) - REC is enabled for External Diode 2 and External Diode 3.  
‘1’ - REC is disabled for External Diode 2 and External Diode 3.  
Bit 2 - RANGE - Configures the measurement range and data format of the temperature channels.  
„
‘0’ (default) - The temperature measurement range is 0°C to +127.875°C and the data format is  
binary.  
„
‘1’ -The temperature measurement range is -64°C to +191.875°C and the data format is offset  
binary (see Table 6.2).  
Bit 1 - DAVG_DIS - Disables the dynamic averaging feature on all temperature channels.  
„
‘0’ (default) - The dynamic averaging feature is enabled. All temperature channels will be converted  
with an averaging factor that is based on the conversion rate as shown in Table 6.1.  
„
‘1’ - The dynamic averaging feature is disabled. All temperature channels will be converted with a  
maximum averaging factor of 1x (equivalent to 11-bit conversion). For higher conversion rates, this  
averaging factor will be reduced as shown in Table 6.1.  
Bit 0 - APDD (EMC1414 only) - Disables the anti-parallel diode operation. Beta Compensation is  
disabled on External Diode 2 and 3 regardless of APDD setting. In addition, External Diode 2 Beta  
Configuration register will be ignored.  
„
‘0’ (default) - Anti-parallel diode mode is enabled. Two external diodes will be measured on the  
DP2 and DN2 pins.  
„
‘1’ - Anti-parallel diode mode is disabled. Only one external diode will be measured on the DP2  
and DN2 pins.  
7.5  
Conversion Rate Register  
Table 7.5 Conversion Rate Register  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
04h  
0Ah  
Conversion  
Rate  
06h  
(4/sec)  
R/W  
-
-
-
-
CONV[3:0]  
The Conversion Rate Register controls how often the temperature measurement channels are updated  
and compared against the limits. This register is fully accessible at either address.  
Bits 3-0 - CONV[3:0] - Determines the conversion rate as shown in Table 7.6.  
Table 7.6 Conversion Rate  
CONV[3:0]  
HEX  
3
2
1
0
CONVERSIONS / SECOND  
0h  
1h  
0
0
0
0
0
0
0
1
1 / 16  
1 / 8  
SMSC EMC1413 / EMC1414  
Revision 1.41 (02-23-12)  
DATA3S1HEET