 浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第12页浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第13页浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第14页浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第15页浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第17页浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第18页浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第19页浏览型号EMC1403-2-YZT-TR的Datasheet PDF文件第20页  
1°C Temperature Sensor with Beta Compensation  
Datasheet  
4.6  
Alert Response Address  
The ALERT output can be used as a processor interrupt or as an SMBus Alert.  
When it detects that the ALERT pin is asserted, the host will send the Alert Response Address (ARA)  
to the general address of 0001_100xb. All devices with active interrupts will respond with their client  
address as shown in Table 4.6.  
Table 4.6 Alert Response Address Protocol  
ALERT  
RESPONSE  
ADDRESS  
DEVICE  
ADDRESS  
START  
1 -> 0  
RD  
ACK  
NACK  
STOP  
0001_100  
1
0
1001_1000  
1
0 -> 1  
The EMC1403 and EMC1404 will respond to the ARA in the following way:  
1. Send Slave Address and verify that full slave address was sent (i.e. the SMBus communication  
from the device was not prematurely stopped due to a bus contention event).  
2. Set the MASK bit to clear the ALERT pin.  
APPLICATION NOTE: The ARA does not clear the Status Register and if the MASK bit is cleared prior to the Status  
Register being cleared, the ALERT pin will be reasserted.  
4.7  
4.8  
SMBus Address  
The EMC1403 and EMC1404 respond to hard-wired SMBus slave address as shown in Table 1.1.  
Note: Other addresses are available. Contact SMSC for more information.  
SMBus Timeout  
The EMC1403 and EMC1404 support SMBus Timeout. If the clock line is held low for longer than  
30ms, the device will reset its SMBus protocol. This function can be enabled by setting the TIMEOUT  
bit in the Consecutive Alert Register (see Section 6.12).  