 浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第15页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第16页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第17页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第18页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第20页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第21页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第22页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第23页  
1°C Triple Temperature Sensor with Hotter of Two Zones  
Datasheet  
The Configuration Register controls the basic functionality of the EMC1063. The bits are described  
below:  
Bit 6 - STANDBY- controls the ADC conversions and power modes of the part.  
„
'0' - The device is in the run operating mode. The ADC is converting at the user-programmed  
conversion rate.  
„
'1' - (default) The device is in the standby operating mode (see Section 3.1).  
Bit 2-0 - CR<2:0> - determines the conversion rate for the temperature monitoring per Table 4.4.  
Table 4.4 Conversion Rate  
CR<2:0>  
CONVERSIONS / SECOND  
2
1
0
(CONVERSION TIME)  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Reserved  
Reserved  
Reserved  
1 Conversion / sec  
2 Conversions / sec  
4 Conversions / sec (default)  
8 Conversions / sec  
16 Conversions / sec  
4.5  
Configuration 2 Register - (04h)  
Table 4.5 Configuration 2 Register  
ADDR  
04h  
REGISTER  
CFG2  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
-
-
-
-
MAX_RES  
DA_n COMP REC 08h  
The Configuration 2 Register controls the basic functionality of the EMC1063 that is NOT compatible  
with the EMC1023.  
Bit 3 - MAX_RES - controls the external diode conversion time during dynamic averaging. Although  
the dynamic averaging may be used to increase the ADC resolution, only 11 bits of data are available  
in the temperature registers.  
„
‘0’ - the dynamic averaging will set the ADC averaging factor at 1x when the conversion rate is set  
at 16 conversions per second and 2x at conversion rates lower than 16 per second.  
„
‘1’ (default) - the dynamic averaging will set the ADC averaging factor at 1x when the conversion  
rate is set at 16 conversions per second, 2x at 8 conversions / second and 4x at conversion rates  
lower than 8 per second.  
Bit 2 - DA_n - controls the dynamic digital averaging circuitry. See Section 3.3.2.  
„
‘0’ (default) - dynamic averaging is enabled. Depending on the selected conversion rate, the ADC  
averaging factor is increased for the external diodes.  
SMSC EMC1063  
Revision 1.37 (02-05-07)  