 浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第7页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第8页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第9页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第10页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第12页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第13页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第14页浏览型号EMC1063-4-ACZL-TR的Datasheet PDF文件第15页  
1°C Triple Temperature Sensor with Hotter of Two Zones  
Datasheet  
Chapter 3 Product Description  
The EMC1063 is an SMBus sensor that monitors three temperature zones for use in a personal  
computer or embedded environment. The part may be used as a companion to one of SMSC’s broad  
line of SIO host devices to perform fan control and thermal management.  
The EMC1063 is designed to operate with two AMD thermal diodes. The External diode 2 channel can  
be configured with the Resistance Error Correction feature enabled to measure a discrete 2N3904  
diode. A typical system is shown in Figure 3.1.  
CPU  
EMC1063  
Host  
DP1  
Thermal  
diode  
DN1  
SMBus  
Interface  
SMBus  
DP2  
DN2  
Thermal  
diode  
Internal  
Diode  
CPU  
Figure 3.1 EMC1063 Diode System  
3.1  
Power Modes  
The EMC1063 has two power modes.  
„
Run Mode - In this mode, the temperature monitors are active and converting at the programmed  
conversion rate. The average power dissipation will depend on the conversion rate. When the  
EMC1063 is not actively converting a channel, it goes into a lower power wait state.  
„
Standby Mode (power-up default) - in this mode, the EMC1063 is put into a low power state. In the  
standby mode, temperature monitoring is disabled. The device will still respond to SMBus  
commands.  
3.2  
3.3  
One Shot During Standby Mode  
The EMC1063 supports a One-Shot command when it is in Standby Mode. Writing to the One-Shot  
register will cause the device to power up, perform 1 full set of temperature conversions, then return  
to Standby Mode.  
Operation During Run Mode  
When the device is active, there are two modes of operation available.  
„
Normal Mode (power-up default) - In this mode of operation, the EMC1063 continuously samples  
and updates all of its temperature channels.  
„
Hotter of Two Mode - In this mode, the EMC1063 continuously samples and then compares the  
two remote zones. The hotter of the two remote zones is loaded into the External Diode 2 Data  
Registers. In addition, the HOTTER bit in the Status register is set or cleared to indicate which  
external diode zone is hotter. If the two remote zones are exactly equal to each other, then the  
SMSC EMC1063  
Revision 1.37 (02-05-07)  
DATAS11HEET