 浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第14页浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第15页浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第16页浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第17页浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第19页浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第20页浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第21页浏览型号EMC1053-ACZL-TR的Datasheet PDF文件第22页  
1°C Triple Temperature Sensor with Resistance Error Correction & Hotter of Two Zones  
Datasheet  
During Power on Reset (POR), the default values are stored in the registers. A POR is initiated when  
power is first applied to the part and the voltage on the VDD supply surpasses the POR level as  
specified in the electrical characteristics. Any reads to undefined registers will return 00h. Writes to  
undefined registers will not have an effect.  
The EMC1053 uses an interlock mechanism that will update the Low byte of a particular monitor when  
the High Byte is read. This prevents changes in register content when the ADC updates between  
successive reads.  
4.1  
Legacy Temperature Data Registers (00h, 23h, 01h, 10h, F8h,  
F9h)  
As shown in Table 4.1, each temperature monitor has two data registers. The 11 bit temperature data  
is stored aligned to the left resulting in the High Byte containing temperature in 1°C steps and the Low  
Byte containing fractions of a degree.  
4.2  
4.3  
Extended Format Temperature Registers (FAh-FDh)  
The Extended Format Temperature Registers store only the external diode temperatures in the  
extended data format. This is because, due to the operating range limitations of the EMC1053, the  
internal temperature could not benefit from the extended temperature range. Like the Legacy data  
formatting, the data is stored in two registers per temperature channel.  
Status Register - 02h  
Table 4.2 Status Register  
ADDR  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
D2  
B0  
D1  
DEFAULT  
02h  
Status  
Busy  
-
-
HOTTER  
-
-
00h  
The Status Register is a read only register and returns the operational status of the part. External diode  
faults are indicated by bits 1 and 0. If either bit is set to ‘1’, then a diode fault has occurred. When a  
diode fault occurs, the D1 or D2 status bit is set, but otherwise the data remains unchanged.  
Bit 7 - Busy - indicates that the ADC is currently converting a temperature.  
Bit 4 - HOTTER - during Hotter of Two mode, this bit indicates which of the external diode channels  
is hotter. If this bit is ‘0’, then External Diode 1 is hotter or equal to External Diode 2. If this bit is ‘1’,  
then External Diode 2 is hotter than External Diode 1. During normal operation, this bit will always read  
a ‘0’.  
Bit 1 - D2 - indicates that a diode fault has occurred on External Diode 2.  
Bit 0 - D1 - indicates that a diode fault has occurred on External Diode 1.  
4.4  
Configuration Register (03h Read, 09h Write)  
Table 4.3 Configuration Register  
ADDR  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
03h Read, Config  
09h Write  
-
STANDBY  
-
-
-
CR<2:0>  
45h  
Revision 1.37 (02-05-07)  
SMSC EMC1053  
DATA1S8HEET