1°C Multiple Temperature Sensor with HW Thermal Shutdown & Hottest of Thermal Zones
Datasheet
5.4
Configuration Register
Table 5.5 Configuration Register
ADDR
R/W
REGISTER
B7
B6
B5
B4
B3
B2
B1
B0
DEFAULT
03h
09h
R/W
Config
-
RUN /
STOP
-
-
-
DAVG_
DIS
-
00h
The Configuration Register controls the basic operation of the device. This register is fully accessible
at either address.
Bit 6 - RUN / STOP - Controls Active/Standby modes.
‘0’ (default) - The device is in Active mode and converting on all channels.
‘1’ -The device is in Standby mode and not converting.
Bit 1 - DAVG_DIS - Disables the dynamic averaging feature on all temperature channels (see
Section 4.2.6).
‘0’ (default) - The dynamic averaging feature is enabled. All temperature channels will be converted
with an averaging factor that is based on the conversion rate as shown in Table 4.1.
‘1’ - The dynamic averaging feature is disabled. All temperature channels will be converted with a
maximum averaging factor of 1x (equivalent to 11-bit conversion). For higher conversion rates (i.e.
more conversions per second), this averaging factor will be reduced as shown in Table 4.1.
5.5
Conversion Rate Register
Table 5.6 Conversion Rate Register
ADDR
R/W
REGISTER
B7
B6
B5
B4
B3
B2
B1
B0
DEFAULT
04h
0Ah
R/W
Conversion
Rate
-
-
-
-
CONV[2:0]
06h
(4/sec)
The Conversion Rate Register controls how often the temperature measurement channels are updated
and compared against the limits. This register is fully accessible at either address.
Bits 3-0 - CONV[3:0] - Determines the conversion rate as shown in Table 5.7.
Table 5.7 Conversion Rate
CONV[2:0]
2
1
0
CONVERSIONS / SECOND
1
1
1
1
0
0
1
1
0
1
0
1
1
2
4 (default)
Continuous
Revision 0.62 (03-05-08)
SMSC EMC1046/EMC1047
DATA2S4HEET