1°C Triple Temperature Sensor with Beta Compensation and Hotter of Two Zones
Datasheet
4.7
Ideality Configuration Registers (27h - 28h)
Table 4.7 Ideality Configuration Registers
B7 B6 B5 B4 B3 B2
B5 B4 B3 B2
B5 B4 B3 B2
ADDR
REGISTER
B1
B1
B1
B0
B0
B0
DEFAULT
27h
28h
Diode 1 Ideality
Correction Factor
-
-
-
-
12h
(1.008)
Diode 2 Ideality
Correction Factor
12h
(1.008)
The Ideality Configuration Registers store the ideality correction factor that is applied to each external
diode.
The table below shows the ideality factor settings for the Ideality Configuration registers. Shading
indicates power-up default. All codes that are not listed are reserved and should not be used.
Beta Compensation and Resistance Error Correction automatically correct for most diode ideality
errors, therefore it is not recommended that these settings be updated without consulting SMSC.
Table 4.8 Ideality Factor Look Up Table
SETTING
FACTOR
0.9951
SETTING
011000
FACTOR
1.0159
SETTING
101000
FACTOR
1.0377
001000
001001
001010
001011
001100
001101
001110
001111
010000
010001
010010
010011
010100
010101
010110
010111
0.9964
0.9976
0.9989
1.0002
1.0015
1.0028
1.0041
1.0054
1.0067
1.0080
1.0093
1.0106
1.0119
1.0133
1.0146
011001
011010
011011
011100
011101
011110
011111
100000
100001
100010
100011
100100
100101
100110
100111
1.0173
1.0186
1.0199
1.0213
1.0226
1.0240
1.0253
1.0267
1.0280
1.0294
1.0308
1.0321
1.0335
1.0349
1.0363
101001
101010
101011
101100
101101
101110
101111
110000
110001
1.0391
1.0404
1.0418
1.0432
1.0446
1.0460
1.0475
1.0489
1.0503
Revision 1.37 (09-05-06)