1°C Triple Temperature Sensor with Beta Compensation and Hotter of Two Zones  
Datasheet  
CPU  
EMC1043-5  
Host  
DP1  
DN1  
Thermal  
Diode  
SMBus  
Interface  
SMBus  
DP2  
DN2  
Remote diode-connected transistor  
Internal  
Diode  
Figure 3.2 EMC1043-5 Mixed System  
3.1  
Power Modes  
The EMC1043 has two power modes.  
„
Run Mode - In this mode, the temperature monitors are active and converting at the programmed  
conversion rate. The average power dissipation will depend on the conversion rate. When the  
EMC1043 is not actively converting a channel, it goes into a lower power wait state.  
„
Standby Mode (power-up default) - in this mode, the EMC1043 is put into a low power state. In the  
standby mode, temperature monitoring is disabled. The device will still respond to SMBus  
commands.  
3.2  
3.3  
One Shot During Standby Mode  
The EMC1043 supports a One-Shot command when it is in Standby Mode. Writing to the One-Shot  
register will cause the device to power up, perform 1 full set of temperature conversions, then return  
to Standby Mode.  
Operation During Run Mode  
When the device is active, there are two modes of operation available.  
„
Normal Mode (power-up default) - In this mode of operation, the EMC1043 continuously samples  
and updates all of its temperature channels.  
„
Hotter of Two Mode - In this mode, the EMC1043 continuously samples and then compares the  
two remote zones. The hotter of the two remote zones is loaded into the External Diode 2 Data  
Registers. In addition, the HOTTER bit in the Status register is set or cleared to indicate which  
external diode zone is hotter. If the two remote zones are exactly equal to each other, then the  
HOTTER bit is cleared (set to ‘0’), and the results of the two remote zones are stored in their  
respective registers.  
3.3.1  
Conversion Rates  
The EMC1043 may be configured for different conversion rates based on the system requirements.  
The available rates are 1 full set of conversions per second to 16 full sets of conversions per second.  
The conversion rate is configured as described in Section 4.4. The available conversion rates are  
shown in Table 4.4.  
Revision 1.37 (09-05-06)  
SMSC EMC1043  
DATA1S2HEET