欢迎访问ic37.com |
会员登录 免费注册
发布采购

COM20022I3V-HD 参数 Datasheet PDF下载

COM20022I3V-HD图片预览
型号: COM20022I3V-HD
PDF下载: 下载PDF文件 查看货源
内容描述: 10 Mbps的ARCNET ( ANSI 878.1 )控制器2Kx8板载RAM [10 Mbps ARCNET (ANSI 878.1) Controller with 2Kx8 On-Board RAM]
分类和应用: 微控制器和处理器串行IO控制器通信控制器外围集成电路数据传输局域网时钟
文件页数/大小: 83 页 / 482 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号COM20022I3V-HD的Datasheet PDF文件第50页浏览型号COM20022I3V-HD的Datasheet PDF文件第51页浏览型号COM20022I3V-HD的Datasheet PDF文件第52页浏览型号COM20022I3V-HD的Datasheet PDF文件第53页浏览型号COM20022I3V-HD的Datasheet PDF文件第55页浏览型号COM20022I3V-HD的Datasheet PDF文件第56页浏览型号COM20022I3V-HD的Datasheet PDF文件第57页浏览型号COM20022I3V-HD的Datasheet PDF文件第58页  
10 Mbps ARCNET (ANSI 878.1) Controller with 2Kx8 On-Board RAM  
Datasheet  
internal registers may be written to. Since writing a non-zero value to the Node ID Register wakes up the  
core, the Setup1 Register should be written to before the Node ID Register. Until a non-zero value is  
placed into the NID Register, no microcode is executed, no tokens are passed by this node, and no  
reconfigurations are generated by this node. Once a non-zero value is placed in the register, the core  
wakes up, but the node will not attempt to join the network until the TX Enable bit of the Configuration  
Register is set.  
Before setting the TX Enable bit, the software may make some determinations. The software may first  
observe the Receive Activity and the Token Seen bits of the Diagnostic Status Register to verify the health  
of the receiver and the network.  
Next, the uniqueness of the Node ID value placed in the Node ID Register is determined. The TX Enable  
bit should still be a logic "0" until it is ensured that the Node ID is unique. If this node ID already exists, the  
Duplicate ID bit of the Diagnostic Status Register is set after a maximum of 210mS (or 420mS if the ET1  
and ET2 bits are other than 1,1). To determine if another node on the network already has this ID, the  
COM20022I 3V compares the value in the Node ID Register with the DID's of the token, and determines  
whether there is a response to it. Once the Diagnostic Status Register is read, the DUPID bit is cleared.  
The user may then attempt a new ID value, wait 210mS before checking the Duplicate ID bit, and repeat  
the process until a unique Node ID is found. At this point, the TX Enable bit may be set to allow the node  
to join the network. Once the node joins the network, a reconfiguration occurs, as usual, thus setting the  
MYRECON bit of the Diagnostic Status Register.  
The Tentative ID Register may be used to build a network map of all the nodes on the network, even once  
the COM20022I 3V has joined the network. Once a value is placed in the Tentative ID Register, the  
COM20022I 3V looks for a response to a token whose DID matches the Tentative ID Register. The  
software can record this information and continue placing Tentative ID values into the register to continue  
building the network map. A complete network map is only valid until nodes are added to or deleted from  
the network. Note that a node cannot detect the existence of the next logical node on the network when  
using the Tentative ID. To determine the next logical node, the software should read the Next ID Register.  
6.6  
Improved Diagnostics  
The COM20022I 3V allows the user to better manage the operation of the network through the use of the  
internal Diagnostic Status Register.  
A high level on the My Reconfiguration (MYRECON) bit indicates that the Token Reception Timer of this  
node expired, causing a reconfiguration by this node. After the Reconfiguration (RECON) bit of the Status  
Register interrupts the microcontroller, the interrupt service routine will typically read the MYRECON bit of  
the Diagnostic Status Register. Reading the Diagnostic Status Register resets the MYRECON bit.  
Successive occurrences of a logic "1" on the MYRECON bit indicates that a problem exists with this node.  
At that point, the transmitter should be disabled so that the entire network is not held down while the node  
is being evaluated.  
The Duplicate ID (DUPID) bit is used before the node joins the network to ensure that another node with  
the same ID does not exist on the network. Once it is determined that the ID in the Node ID Register is  
unique, the software should write a logic "1" to bit 5 of the Configuration Register to enable the basic  
transmit function. This allows the node to join the network.  
The Receive Activity (RCVACT) bit of the Diagnostic Status Register will be set to a logic "1" whenever  
activity (logic "1") is detected on the RXIN pin.  
The Token Seen (TOKEN) bit is set to a logic "1" whenever any token has been seen on the network  
(except those tokens transmitted by this node).  
The RCVACT and TOKEN bits may help the user to troubleshoot the network or the node. If unusual  
events are occurring on the network, the user may find it valuable to use the TXEN bit of the Configuration  
Revision 02-27-06  
Page 54  
SMSC COM20022I 3V  
DATASHEET  
 复制成功!