NETWORK RECONFIGURATION. The ET2 and  
ET1 bits of the Configuration Register allow the  
network to operate over longer distances than the  
2 miles stated earlier. The logic levels on these  
bits control the maximum distances over which the  
COM20020 can operate by controlling the three  
timeout values described above. For proper  
network operation, all COM20020's connected to  
the same network must have the same Response  
Time, Idle Time, and Reconfiguration Time.  
ALERT  
BURST  
EOT  
DID  
DID  
LINE PROTOCOL  
The ARCNET line protocol is considered  
isochronous because each byte is preceded by a  
start interval and ended with a stop interval. Unlike  
asynchronous protocols, there is a constant  
amount of time separating each data byte. On a 5  
Mbps network, each byte takes exactly 11 clock  
intervals of 200ns each. As a result, one byte is  
transmitted every 2.2 μS and the time to transmit  
a message can be precisely determined. The line  
idles in a spacing (logic "0") condition. A logic "0"  
is defined as no line activity and a logic "1" is  
defined as a negative pulse of 100nS duration. A  
transmission starts with an ALERT BURST  
consisting of 6 unit intervals of mark (logic "1").  
Eight bit data characters are then sent, with each  
character preceded by 2 unit intervals of mark and  
one unit interval of space.  
Five types of  
transmission can be performed as described  
below:  
Invitations To Transmit  
An Invitation To Transmit is used to pass the  
token from one node to another and is sent by the  
following sequence:  
An ALERT BURST  
An EOT (End Of Transmission: ASCII code  
04H)  
Two (repeated) DID (Destination ID)  
characters  
11  