 浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第33页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第34页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第35页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第36页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第38页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第39页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第40页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第41页  
3 Channel Capacitive Touch Sensor with 3 LED Drivers  
Datasheet  
Table 5.19 SAMP_TIME Bit Decode (continued)  
SAMP_TIME[1:0]  
1
0
SAMPLE TIME  
1
1
2.56ms  
Bits 1 - 0 - CYCLE_TIME[1:0] - Determines the overall cycle time for all measured channels during  
normal operation as shown in Table 5.20. All measured channels are sampled at the beginning of the  
cycle time. If additional time is remaining, then the device is placed into a lower power state for the  
remaining duration of the cycle.  
Table 5.20 CYCLE_TIME Bit Decode  
CYCLE_TIME[1:0]  
1
0
OVERALL CYCLE TIME  
0
0
1
1
0
1
0
1
35ms  
70ms (default)  
105ms  
140ms  
APPLICATION NOTE: The programmed cycle time is only maintained if the total averaging time for all samples is  
less than the programmed cycle. The AVG[2:0] bits will take priority so that if more samples  
are required than would normally be allowed during the cycle time, the cycle time will be  
extended as necessary to accommodate the number of samples to be measured.  
5.11  
Calibration Activate Register  
Table 5.21 Calibration Activate Register  
ADDR  
26h  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Calibration  
Activate  
CS3_  
CAL  
CS2_  
CAL  
CS1_  
CAL  
R/W  
-
-
-
00h  
The Calibration Activate register forces the respective sensor inputs to be re-calibrated affecting both  
the analog and digital blocks. During the re-calibration routine, the sensor inputs will not detect a press  
for up to 600ms and the Sensor Input Base Count register values will be invalid. During this time, any  
press on the corresponding sensor pads will invalidate the re-calibration. When finished, the CALX[9:0]  
bits will be updated (see Section 5.39).  
When the corresponding bit is set, the device will perform the calibration and the bit will be  
automatically cleared once the re-calibration routine has finished.  
Bit 2 - CS3_CAL - When set, the CS3 input is re-calibrated. This bit is automatically cleared once the  
sensor input has been re-calibrated successfully.  
Bit 1 - CS2_CAL - When set, the CS2 input is re-calibrated. This bit is automatically cleared once the  
sensor input has been re-calibrated successfully.  
SMSC CAP1133  
Revision 1.32 (01-05-12)  
DATA3S7HEET