欢迎访问ic37.com |
会员登录 免费注册
发布采购

CAP1133-1-AIA-TR 参数 Datasheet PDF下载

CAP1133-1-AIA-TR图片预览
型号: CAP1133-1-AIA-TR
PDF下载: 下载PDF文件 查看货源
内容描述: [LED Driver]
分类和应用: 驱动接口集成电路
文件页数/大小: 71 页 / 521 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第22页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第23页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第24页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第25页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第27页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第28页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第29页浏览型号CAP1133-1-AIA-TR的Datasheet PDF文件第30页  
3 Channel Capacitive Touch Sensor with 3 LED Drivers  
Datasheet  
Table 5.1 Register Set in Hexadecimal Order (continued)  
REGISTER  
ADDRESS  
DEFAULT  
VALUE  
R/W  
REGISTER NAME  
FUNCTION  
PAGE  
Stores a fixed value that identifies  
SMSC  
FEh  
FFh  
R
Manufacturer ID  
5Dh  
83h  
Page 64  
Stores a fixed value that represents  
the revision number  
R
Revision  
Page 64  
During Power-On-Reset (POR), the default values are stored in the registers. A POR is initiated when  
power is first applied to the part and the voltage on the VDD supply surpasses the POR level as  
specified in the electrical characteristics. Any reads to undefined registers will return 00h. Writes to  
undefined registers will not have an effect.  
When a bit is “set”, this means that the user writes a logic ‘1’ to it. When a bit is “cleared”, this means  
that the user writes a logic ‘0’ to it.  
5.1  
Main Control Register  
Table 5.2 Main Control Register  
ADDR  
00h  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
R/W  
Main Control  
GAIN[1:0]  
STBY  
DSLEEP  
-
-
-
INT  
00h  
The Main Control register controls the primary power state of the device.  
Bits 7 - 6 - GAIN[1:0] - Controls the gain used by the capacitive touch sensing circuitry. As the gain is  
increased, the effective sensitivity is likewise increased as a smaller delta capacitance is required to  
generate the same delta count values. The sensitivity settings may need to be adjusted along with the  
gain settings such that data overflow does not occur.  
APPLICATION NOTE: The gain settings apply to both Standby and Active states.  
Table 5.3 GAIN Bit Decode  
GAIN[1:0]  
1
0
CAPACITIVE TOUCH SENSOR GAIN  
0
0
1
1
0
1
0
1
1
2
4
8
Bit 5 - STBY - Enables Standby.  
„
„
‘0’ (default) - Sensor input scanning is active and LEDs are functional.  
‘1’ - Capacitive touch sensor input scanning is limited to the sensor inputs set in the Standby  
Channel register (see Section 5.20). The status registers will not be cleared until read. LEDs that  
are linked to capacitive touch sensor inputs will remain linked and active. Sensor inputs that are  
Revision 1.32 (01-05-12)  
SMSC CAP1133  
DATA2S6HEET