 浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第76页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第77页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第78页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第79页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第81页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第82页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第83页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第84页  
8 Channel Capacitive Touch Sensor with 2 LED Drivers  
Datasheet  
Table 5.65 Off Delay Decode (continued)  
OFF DELAY[3:0] BIT DECODE  
3
2
1
0
OFF DELAY (TOFF_DLY)  
1
1
1
1
0
0
0
1
0
1
1
0
1
0
1
0
3.0s  
3.5s  
4.0s  
4.5s  
5.0s  
All others  
5.39  
Sensor Input Calibration Registers  
Table 5.66 Sensor Input Calibration Registers  
ADDR  
REGISTER  
R/W  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Sensor Input 1  
Calibration  
B1h  
R
CAL1_9  
CAL1_8  
CAL1_7  
CAL1_6  
CAL1_5 CAL1_4  
CAL2_5 CAL2_4  
CAL3_5 CAL3_4  
CAL4_5 CAL4_4  
CAL5_5 CAL5_4  
CAL6_5 CAL6_4  
CAL7_5 CAL7_4  
CAL8_5 CAL8_4  
CAL1_3  
CAL1_2  
CAL2_2  
CAL3_2  
CAL4_2  
CAL5_2  
CAL6_2  
CAL7_2  
CAL8_2  
00h  
Sensor Input 2  
Calibration  
B2h  
B3h  
B4h  
B5h  
B6h  
B7h  
B8h  
R
R
R
R
R
R
R
CAL2_9  
CAL3_9  
CAL4_9  
CAL5_9  
CAL6_9  
CAL7_9  
CAL8_9  
CAL2_8  
CAL3_8  
CAL4_8  
CAL5_8  
CAL6_8  
CAL7_8  
CAL8_8  
CAL2_7  
CAL3_7  
CAL4_7  
CAL5_7  
CAL6_7  
CAL7_7  
CAL8_7  
CAL2_6  
CAL3_6  
CAL4_6  
CAL5_6  
CAL6_6  
CAL7_6  
CAL8_6  
CAL2_3  
CAL3_3  
CAL4_3  
CAL5_3  
CAL6_3  
CAL7_3  
CAL8_3  
00h  
00h  
00h  
00h  
00h  
00h  
00h  
Sensor Input 3  
Calibration  
Sensor Input 4  
Calibration  
Sensor Input 5  
Calibration  
Sensor Input 6  
Calibration  
Sensor Input 7  
Calibration  
Sensor Input 8  
Calibration  
Sensor Input  
Calibration  
LSB 1  
B9h  
BAh  
R
R
CAL4_1  
CAL8_1  
CAL4_0  
CAL8_0  
CAL3_1  
CAL7_1  
CAL3_0  
CAL7_0  
CAL2_1 CAL2_0  
CAL6_1 CAL6_0  
CAL1_1  
CAL5_1  
CAL1_0  
CAL5_0  
00h  
00h  
Sensor Input  
Calibration  
LSB 2  
The Sensor Input Calibration registers hold the 10-bit value that represents the last calibration value.  