欢迎访问ic37.com |
会员登录 免费注册
发布采购

CAP1128-1-BP-TR 参数 Datasheet PDF下载

CAP1128-1-BP-TR图片预览
型号: CAP1128-1-BP-TR
PDF下载: 下载PDF文件 查看货源
内容描述: [LED Driver]
分类和应用: 驱动接口集成电路
文件页数/大小: 88 页 / 585 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第53页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第54页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第55页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第56页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第58页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第59页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第60页浏览型号CAP1128-1-BP-TR的Datasheet PDF文件第61页  
8 Channel Capacitive Touch Sensor with 2 LED Drivers  
Datasheet  
„
‘1’ - If an MTP event occurs, the ALERT# pin will be asserted.  
5.16  
Multiple Touch Pattern Register  
Table 5.28 Multiple Touch Pattern Register  
B6 B5 B4 B3  
ADDR  
R/W  
REGISTER  
B7  
B2  
B1  
B0  
DEFAULT  
Multiple  
Touch  
Pattern  
CS8_  
PTRN  
CS7_  
PTRN  
CS6_  
PTRN  
CS5_  
PTRN  
CS4_  
PTRN  
CS3_  
PTRN  
CS2_  
PTRN  
CS1_  
PTRN  
2Dh  
R/W  
FFh  
The Multiple Touch Pattern register acts as a pattern to identify an expected sensor input profile for  
diagnostics or other significant events. There are two methods for how the Multiple Touch Pattern  
register is used: as specific sensor inputs or number of sensor input that must exceed the MTP  
threshold or have Noise Flag Status bits set. Which method is used is based on the COMP_PTRN bit  
(see Section 5.15). The methods are described below.  
1. Specific Sensor Inputs: If, during a single polling cycle, the specific sensor inputs above the MTP  
threshold or with Noise Flag Status bits set match those bits set in the Multiple Touch Pattern  
register, an MTP event is flagged.  
2. Number of Sensor Inputs: If, during a single polling cycle, the number of sensor inputs with a delta  
count above the MTP threshold or with Noise Flag Status bits set is equal to or greater than the  
number of pattern bits set, an MTP event is flagged.  
Bit 7 - CS8_PTRN - Determines whether CS8 is considered as part of the Multiple Touch Pattern.  
„
„
‘0’ - CS8 is not considered a part of the pattern.  
‘1’ - CS8 is considered a part of the pattern, or the absolute number of sensor inputs that must  
have a delta count greater than the MTP threshold or have the Noise Flag Status bit set is  
increased by 1.  
Bit 6 - CS7_PTRN - Determines whether CS7 is considered as part of the Multiple Touch Pattern.  
Bit 5 - CS6_PTRN - Determines whether CS6 is considered as part of the Multiple Touch Pattern.  
Bit 4 - CS5_PTRN - Determines whether CS5 is considered as part of the Multiple Touch Pattern.  
Bit 3 - CS4_PTRN - Determines whether CS4 is considered as part of the Multiple Touch Pattern.  
Bit 2 - CS3_PTRN - Determines whether CS3 is considered as part of the Multiple Touch Pattern.  
Bit 1 - CS2_PTRN - Determines whether CS2 is considered as part of the Multiple Touch Pattern.  
Bit 0 - CS1_PTRN - Determines whether CS1 is considered as part of the Multiple Touch Pattern.  
5.17  
Recalibration Configuration Register  
Table 5.29 Recalibration Configuration Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
NO_  
CLR_  
INTD  
NO_  
CLR_  
NEG  
Recalibration  
Configuration  
BUT_  
LD_TH  
NEG_DELTA_  
CNT[1:0]  
2Fh  
R/W  
CAL_CFG[2:0]  
8Ah  
SMSC CAP1128  
Revision 1.32 (01-05-12)  
DATA5S7HEET