欢迎访问ic37.com |
会员登录 免费注册
发布采购

CAP1088-1-CP-TR 参数 Datasheet PDF下载

CAP1088-1-CP-TR图片预览
型号: CAP1088-1-CP-TR
PDF下载: 下载PDF文件 查看货源
内容描述: 8通道电容式触摸传感器,具有8个LED驱动器 [8 Channel Capacitive Touch Sensor with 8 LED Drivers]
分类和应用: 驱动器模拟IC传感器信号电路
文件页数/大小: 72 页 / 994 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第59页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第60页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第61页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第62页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第64页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第65页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第66页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第67页  
8 Channel Capacitive Touch Sensor with 8 LED Drivers  
Datasheet  
5.32 LED Duty Cycle Registers  
Table 5.50 LED Duty Cycle Registers  
B7 B6 B5 B4 B3  
ADDR  
R/W  
REGISTER  
B2  
B1  
B0  
DEFAULT  
LED Pulse 1  
Duty Cycle  
90h  
R/W  
P1_MAX_DUTY[3:0]  
P2_MAX_DUTY[3:0]  
BR_MAX_DUTY[3:0]  
DR_MAX_DUTY[3:0]  
P1_MIN_DUTY[3:0]  
P2_MIN_DUTY[3:0]  
BR_MIN_DUTY[3:0]  
DR_MIN_DUTY[3:0]  
F0h  
LED Pulse 2  
Duty Cycle  
91h  
92h  
93h  
R/W  
R/W  
R/W  
F0h  
F0h  
F0h  
LED Breathe  
Duty Cycle  
Direct Duty  
Cycle  
The LED Duty Cycle registers determine the minimum and maximum duty cycle settings used for the  
LED for each LED behavior. These settings affect the brightness of the LED when it is fully off and  
fully on.  
The LED driver duty cycle will ramp up from the minimum duty cycle (see Section 5.32) to the  
maximum duty cycle and back down again.  
APPLICATION NOTE: Changes to the Duty Cycle settings will be applied immediately. When the respective register  
is written, the LED output will be reset to the minimum (or maximum) setting and restarted  
at the updated settings.  
APPLICATION NOTE: Upon power on reset (or upon release of the RESET pin), the first breath will breathe from  
100% (or 0% duty cycle as determined by the polarity registers) to the programmed minimum  
(or maximum as determined by the polarity registers) and then proceed normally.  
APPLICATION NOTE: If the min duty cycle and the max duty cycle are set to the same % then the minimum duty  
cycle will automatically be changed to the next lower setting. For example, if the maximum  
duty cycle were set at 1100b (35%) and the minimum duty cycle were set at 1101b (35%),  
the device will automatically use the minimum value at 1100b (25%).  
Bits 7 - 4 - X_MAX_DUTY[3:0] - Determines the maximum PWM duty cycle for the LED drivers as  
shown in Table 5.51  
Bits 3 - 0 - X_MIN_DUTY[3:0] - Determines the minimum PWM duty cycle for the LED drivers as  
shown in Table 5.51.  
Table 5.51 LED Duty Cycle Decode  
X_MAX/MIN_DUTY [3:0]  
3
2
1
0
MAXIMUM DUTY CYCLE  
MINIMUM DUTY CYCLE  
0
0
0
0
0
0
0
0
0
1
0
0
1
1
0
0
1
0
1
0
1%  
2%  
3%  
4%  
5%  
0%  
1%  
2%  
3%  
4%  
SMSC CAP1088  
Revision 1.1 (08-05-09)  
DATA6S3HEET