 浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第43页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第44页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第45页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第46页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第48页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第49页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第50页浏览型号CAP1088-1-CP-TR的Datasheet PDF文件第51页  
8 Channel Capacitive Touch Sensor with 8 LED Drivers  
Datasheet  
5.15 Recalibration Configuration Register  
Table 5.23 Recalibration Configuration Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Recalibration  
Configuration  
BUT_  
LD_TH  
NEG_DELTA_  
CNT[1:0]  
2Fh  
R/W  
-
-
CAL_CFG[2:0]  
8Bh  
The Recalibration Configuration register controls the automatic re-calibration routine settings as well  
as advanced controls to program the Sensor Threshold register settings.  
Bit 7 - BUT_LD_TH - Enables setting all Sensor Threshold registers by writing to the Sensor 1  
Threshold register.  
„
„
‘0’ - Each Sensor X Threshold register is updated individually.  
‘1’ (default) - Writing the Sensor 1 Threshold register will automatically overwrite the Sensor  
Threshold registers for all sensors (Sensor Threshold 1 through Sensor Threshold 8). The  
individual Sensor X Threshold registers (Sensor 2 Threshold through Sensor 8 Threshold) can be  
individually updated at any time.  
Bits 4 - 3 - NEG_DELTA_CNT[1:0] - Determines the number of negative delta counts necessary to  
trigger a digital re-calibration as shown in Table 5.24.  
Table 5.24 NEG_DELTA_CNT Bit Decode  
NEG_DELTA_CNT[1:0]  
NUMBER OF CONSECUTIVE NEGATIVE DELTA  
1
0
COUNT VALUES  
0
0
1
1
0
1
0
1
8
16 (default)  
32  
None (disabled)  
Bits 2 - 0 - CAL_CFG[2:0] - Determines the update time and number of samples of the automatic re-  
calibration routine. The settings applies to all sensors universally (though individual sensors can be  
configured to support re-calibration - see Section 5.11).  
Table 5.25 CAL_CFG Bit Decode  
CAL_CFG[2:0]  
RECALIBRATION  
SAMPLES (SEE  
UPDATE TIME (SEE  
2
1
0
Note 5.1)  
Note 5.2)  
0
0
0
0
1
0
0
1
1
0
0
1
0
1
0
16  
32  
16  
32  
64  
64  
256  
256  
256 (default)  
1024  
SMSC CAP1088  
Revision 1.1 (08-05-09)  
DATA4S7HEET