8 Channel Capacitive Touch Sensor with 8 LED Drivers  
Datasheet  
Table 5.17 CYCLE_TIME Bit Decode  
CYCLE_TIME[1:0]  
1
0
OVERALL CYCLE TIME  
0
0
1
1
0
1
0
1
35ms  
70ms (default)  
105ms  
140ms  
APPLICATION NOTE: The programmed cycle time is only maintained if the total averaging time for all samples is  
less than the programmed cycle. The AVG[2:0] bits will take priority so that if more samples  
are required than would normally be allowed during the cycle time, the cycle time will be  
extended as necessary to accommodate the number of samples to be measured.  
5.11 Calibration Activate Registers  
Table 5.18 Calibration Activate Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Calibration  
Activate  
26h  
R/W  
CS8_CAL  
CS7_CAL  
CS6_CAL  
CS5_CAL  
CS4_CAL  
CS3_CAL  
CS2_CAL  
CS1_CAL  
FFh  
The Calibration Activate register force the respective sensors to be re-calibrated. When a bit is set,  
the corresponding Capacitive Touch Sensor will be re-calibrated and the bit will be automatically  
cleared once the re-calibration routine has finished. During the re-calibration routine, the sensors will  
not detect a press for up to 600ms and the Sensor Base Count register values will be invalid. During  
this time, any press on the corresponding sensors will invalidate the re-calibration.  
Bit 7 - CS8_CAL - When set, the CS8 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Bit 6 - CS7_CAL - When set, the CS7 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Bit 5 - CS6_CAL - When set, the CS6 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Bit 4 - CS5_CAL - When set, the CS5 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Bit 3 - CS4_CAL - When set, the CS4 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Bit 2 - CS3_CAL - When set, the CS3 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Bit 1 - CS2_CAL - When set, the CS2 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Bit 0 - CS1_CAL - When set, the CS1 input is re-calibrated. This bit is automatically cleared once the  
sensor has been re-calibrated successfully.  
Revision 1.1 (08-05-09)  