8 Channel Capacitive Touch Sensor with 8 LED Drivers
Datasheet
Table 5.17 CYCLE_TIME Bit Decode
CYCLE_TIME[1:0]
1
0
OVERALL CYCLE TIME
0
0
1
1
0
1
0
1
35ms
70ms (default)
105ms
140ms
APPLICATION NOTE: The programmed cycle time is only maintained if the total averaging time for all samples is
less than the programmed cycle. The AVG[2:0] bits will take priority so that if more samples
are required than would normally be allowed during the cycle time, the cycle time will be
extended as necessary to accommodate the number of samples to be measured.
5.11 Calibration Activate Registers
Table 5.18 Calibration Activate Registers
ADDR
R/W
REGISTER
B7
B6
B5
B4
B3
B2
B1
B0
DEFAULT
Calibration
Activate
26h
R/W
CS8_CAL
CS7_CAL
CS6_CAL
CS5_CAL
CS4_CAL
CS3_CAL
CS2_CAL
CS1_CAL
FFh
The Calibration Activate register force the respective sensors to be re-calibrated. When a bit is set,
the corresponding Capacitive Touch Sensor will be re-calibrated and the bit will be automatically
cleared once the re-calibration routine has finished. During the re-calibration routine, the sensors will
not detect a press for up to 600ms and the Sensor Base Count register values will be invalid. During
this time, any press on the corresponding sensors will invalidate the re-calibration.
Bit 7 - CS8_CAL - When set, the CS8 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Bit 6 - CS7_CAL - When set, the CS7 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Bit 5 - CS6_CAL - When set, the CS6 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Bit 4 - CS5_CAL - When set, the CS5 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Bit 3 - CS4_CAL - When set, the CS4 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Bit 2 - CS3_CAL - When set, the CS3 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Bit 1 - CS2_CAL - When set, the CS2 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Bit 0 - CS1_CAL - When set, the CS1 input is re-calibrated. This bit is automatically cleared once the
sensor has been re-calibrated successfully.
Revision 1.1 (08-05-09)
SMSC CAP1088
DATA4S4HEET