6 Channel Capacitive Touch Sensor with 6 LED Drivers
Datasheet
Chapter 7 Revision History
Table 7.1 Customer Revision History
SECTION/FIGURE/ENTRY
REVISION LEVEL & DATE
CORRECTION
Rev. 1.1 (08-05-09)
Features
“TBD” replaced with “3uA” under Low Power
Operation
General Description
Chapter 1, Pin Description
Deep sleep drawing “5uA” of current changed to
“3uA”
Application Note added: “The SPI_CS# pin should
be grounded when SMBus, I2C, or BC-Link
communications are used.”
Pin description table updated: Added to pin
function description for RESET pin: “This pin
contains an internal 50uA pull-down current.”
Table 2.2, "Electrical
Specifications"
Table updated:
- Current Measurement, ISTBY - changed the
typical column to 160, max to 210. Changed the
conditions to read: " Standby state active, one
sensor monitored, no LED active, default
conditions (8 avg, 70ms cycle time)"
- Current Measurement, IDSLEEP -changed the
TYP column value to 3 and max to 10.
- Base Capacitance Line - changed the name to
"Maximum Base Capacitance". Removed the value
in the MIN column and MAX column. Added 50 in
the TYP column.
Section 3.1.1, "SMBus (I2C)
Communications"
The following text deleted: “The SPI_CS# pin is not
used and any data presented to this pin will be
ignored.”
and replaced with an application note: “For
SMBus/I2C communications, the SPI_CS# pin is
not used and should be grounded; any data
presented to this pin will be ignored.”
Section 3.1.3, "BC-Link
Communications"
The following application note added: “For BC-Link
communications, the SPI_CS# pin is not used and
should be grounded; any data presented to this pin
will be ignored.”
Table 3.1, "ADDR_COMM
Pin Decode"
Modified table heading, “Pull-Down Resistor” by
adding “(+/- 5%)”
Section 5.28, "LED Pulse 1
Period Register",
Added note describing limitation on operation
Section Table 5.45, "LED
Pulse / Breathe Period
Example" and
Section 5.30, "LED Breathe
Period Register"
Table 5.51, "LED Duty Cycle
Decode"
Updated table for Min and Max columns