6 Channel Capacitive Touch Sensor with 6 LED Drivers  
Datasheet  
Release Detected  
Touch Detected  
Normal – untouched  
operation  
Normal – untouched  
X additional pulses after release  
operation  
(100% - Pulse 2 Min Duty Cycle) *  
Brightness  
LED  
Brightness  
. . .  
Breathe  
and Pulse  
Period  
(100% - Pulse 2 Max Duty Cycle) * Brightness  
(P2_PER)  
Figure 5.3 Pulse 2 Behavior with Non-Inverted Polarity  
Release Detected  
Touch Detected  
Normal – untouched  
operation  
Normal – untouched  
operation  
X additional pulses after release  
Pulse 2 Max Duty Cycle * Brightness  
LED  
Brightness  
. . .  
Breathe  
and Pulse  
Period  
Pulse 2 Min Duty Cycle * Brightness  
Figure 5.4 Pulse 2 Behavior with Inverted Polarity  
5.30 LED Breathe Period Register  
Table 5.47 LED Breathe Period Register  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
5Dh  
LED Breathe  
Period  
BR_  
PER6  
BR_  
PER5  
BR_  
PER4  
BR_  
PER3  
BR_  
PER2  
BR_  
PER1  
BR_  
PER0  
86h  
R/W  
-
The LED Breathe Period register determines the overall period of a breathe operation as determined  
by the LED_CTL registers (see Table 5.43 - setting 11b). Each LSB represents 32ms so that a setting  
of 14h (20d) would represent a period of 640ms. The total range is from 32ms to 4.06 seconds (see  
Table 5.45).  
APPLICATION NOTE: Due to constraints on the LED Drive PWM operation, any Breathe Period less than 160ms  
(05h) may not be achievable. The device will breathe at the minimum period possible as  
determined by the period and min / max duty cycle settings.  