6 Channel Capacitive Touch Sensor with 6 LED Drivers
Datasheet
3.3.2
Block Write
The Block Write is used to write multiple data bytes to a group of contiguous registers as shown in
Table 3.4. It is an extension of the Write Byte Protocol.
APPLICATION NOTE: When using the Block Write protocol, the internal address pointer will be automatically
incremented after every data byte is received. It will wrap from FFh to 00h.
Table 3.4 Block Write Protocol
SLAVE
ADDRESS
REGISTER
ADDRESS
REGISTER
DATA
START
WR
ACK
ACK
ACK
1 ->0
YYYY_YYY
0
0
XXh
0
XXh
0
REGISTER
DATA
REGISTER
DATA
REGISTER
DATA
ACK
ACK
. . .
ACK
STOP
XXh
0
XXh
0
. . .
XXh
0
0 -> 1
3.3.3
SMBus Read Byte
The Read Byte protocol is used to read one byte of data from the registers as shown in Table 3.5.
Table 3.5 Read Byte Protocol
START
SLAVE
ADDRESS
WR
ACK
REGISTER
ADDRESS
ACK
START
CLIENT
ADDRESS
RD
ACK
REGISTER
DATA
NACK
STOP
1->0
YYYY_YYY
0
0
XXh
0
1 ->0
YYYY_YYY
1
0
XXh
1
0 -> 1
3.3.4
Block Read
The Block Read is used to read multiple data bytes from a group of contiguous registers as shown in
Table 3.6. It is an extension of the Read Byte Protocol.
APPLICATION NOTE: When using the Block Read protocol, the internal address pointer will be automatically
incremented after every data byte is received. It will wrap from FFh to 00h.
Table 3.6 Block Read Protocol
START
SLAVE
ADDRESS
WR
ACK
REGISTER
ADDRESS
ACK
START
SLAVE
ADDRESS
RD
ACK
REGISTER
DATA
1->0
YYYY_YYY
0
0
XXh
0
1 ->0
YYYY_YYY
1
0
XXh
ACK
REGISTER
DATA
ACK
REGISTER
DATA
ACK
REGISTER
DATA
ACK
. . .
REGISTER
DATA
NACK
STOP
0
XXh
0
XXh
0
XXh
0
. . .
XXh
1
0 -> 1
3.3.5
SMBus Send Byte
The Send Byte protocol is used to set the internal address register pointer to the correct address
location. No data is transferred during the Send Byte protocol as shown in Table 3.7.
Revision 1.1 (08-05-09)
SMSC CAP1066
DATA1S8HEET