 浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第49页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第50页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第51页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第52页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第54页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第55页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第56页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第57页  
Multiple Channel Capacitive Touch Sensor and LED Driver  
Datasheet  
„
‘1’ The lid closure circuitry is enabled. The device will use the Lid Closure Status registers in  
combination with the Lid Closure Pattern register settings to determine when a Lid Closure Event  
is flagged. In addition, the Noise Status bits are associated with lid closure.  
Bit 1 - COMP_PTRN - Determines how the Lid Closure Status registers are compared against the Lid  
Closure Pattern registers. See Section 5.26, "Lid Closure Pattern Registers" for details on how the Lid  
Closure Pattern registers are used.  
„
‘0’ (default) - The Lid Closure Status registers are not compared directly against the Lid Closure  
Pattern registers. Instead, the number of bits in the Lid Closure Status registers is compared to the  
number of bits in the Lid Closure Pattern registers to determine whether a Lid Closure Event is  
flagged.  
„
‘1’ - The Lid Closure Status registers are compared directly against the Lid Closure Pattern  
registers. If the bits set in the Lid Closure Pattern are also set in the Lid Status registers, then a  
Lid Closure Event is flagged.  
Bit 0 - LID_ALRT - Enables an interrupt if a Lid Closure Event occurs.  
„
„
‘0’ (default) - If a Lid Closure Event occurs, the ALERT pin is not asserted.  
‘1’ - If a Lid Closure Event occurs, the ALERT pin will be asserted.  
5.25 Lid Closure Queue Control Register  
Table 5.35 Lid Closure Queue Control Register  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Lid Closure  
Queue Control  
2Ch  
R/W  
-
-
-
-
-
QUEUE_L_B[2:0]  
02h  
The Lid Closure Queue Control register determines the number of consecutive samples for which a  
single sensor output is above the Lid Closure Threshold before it is flagged.  
A value of 0000b is decoded as 1.  
Bits 2 - 0 - QUEUE_B[2:0] - The number of consecutive samples from an individual sensor necessary  
to set the Lid Closure status bit associated with the sensor. The queue applies individually to all  
sensors (including both buttons and grouped sensors) and applies to setting and clearing the  
respective status bit. Default is 2 consecutive samples.  
5.26 Lid Closure Pattern Registers  
Table 5.36 Lid Closure Pattern Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Lid Closure  
Pattern 1  
2Dh  
R/W  
-
S7_LM  
S6_LM  
S5_LM  
S4_LM  
S3_LM  
S2_LM S1_LM  
7Fh  
Lid Closure  
Pattern 2  
2Eh  
R/W  
S14_LM S13_LM S12_LM  
S11_LM S10_LM S9_LM S8_LM  
7Fh  
The Lid Closure Pattern registers act as a pattern to identify an expected sensor profile that is  
consistent with lid closure. They are only used when lid closure is enabled (see Section 5.24, "Lid  
Closure Configuration Register"). There are two methods for how the Lid Closure Status Registers are  
used with the Lid Closure Pattern registers: as specific sensors that must exceed the lid closure  
threshold or as the number of sensors that must exceed the lid closure threshold. Which method is  