 浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第44页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第45页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第46页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第47页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第49页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第50页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第51页浏览型号CAP1014-2-EZK-TR的Datasheet PDF文件第52页  
Multiple Channel Capacitive Touch Sensor and LED Driver  
Datasheet  
This is the maximum amount of time that a sensor in the Group can detect a button press to  
differentiate between a tap and a press and hold. If a sensor detects a touch for less than or equal to  
the M_PRESS[3:0] settings then, a Tap event is detected.  
The resolution is 35ms the range is from 35ms to 560ms as shown in Table 5.24.  
5.18 Group Configuration Register 2  
Table 5.26 Group Configuration Register 2  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Group  
Configuration 2  
24h  
R/W  
MAX_DUR_G[3:0]  
RPT_RATE_SL[3:0]  
D4h  
The Group Configuration 2 register controls timings associated with the Capacitive Sensor channels 8  
- 14 that are included in the group.  
Bits 7 - 4 - MAX_DUR_G [3:0] - (default 1101b) - Determines the maximum time that a button is  
allowed to be pressed until the Capacitive Touch sensor is recalibrated as shown in Table 5.23.  
Bits 3 - 0 - RPT_RATE_SL[3:0] - (default 0100b) Determines the time duration between interrupt  
assertions when auto repeat is enabled. This setting applies when a slide is detected on the Grouped  
Sensors and acts as the base repeat rate that is adjusted based on the slide speed (see Section 4.5.3).  
The resolution is 35ms the range is from 35ms to 560ms as shown in Table 5.24.  
5.19 Calibration Enable Registers  
Table 5.27 Calibration Enable Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Calibration  
Enable  
G_  
CEN  
S7_  
CEN  
S6_  
CEN  
S5_  
CEN  
S4_  
CEn  
S3_  
CEN  
S2_  
CEN  
S1_  
CEN  
25h  
R/W  
FFh  
The Calibration Enable registers control whether the indicated Capacitive Touch Sensor input is  
automatically re-calibrated. If a sensor is not enabled then the corresponding calibration enable bit is  
ignored.  
Bit 7- G_CEN - Enables all sensors in the group to be re-calibrated simultaneously.  
„
‘0’ - None of the grouped channels are automatically re-calibrated. They can be re-calibrated  
manually by setting the G_CAL bit.  
„
‘1’ (default) - All of the grouped channels are automatically re-calibrated as the CAP1014 samples.  
Bit 6 - S7_CEN - Enables the CS7 input to be re-calibrated automatically.  
„
„
‘0’ - The CS7 input is not automatically re-calibrated.  
‘1’ (default) - The CS7 input is automatically re-calibrated as the CAP1014 samples.  
Bit 5 - S6_CEN - Enables the CS6 input to be re-calibrated automatically.  
Bit 4 - S5_CEN - Enables the CS5 input to be re-calibrated automatically.  
Bit 3 - S4_CEN - Enables the CS4 input to be re-calibrated automatically.  
Bit 2 - S3_CEN - Enables the CS3 input to be re-calibrated automatically.  
Revision 1.65 (08-11-09)  