 浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第42页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第43页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第44页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第45页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第47页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第48页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第49页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第50页  
5 and 6 Channel Capacitive Touch Sensor  
Datasheet  
The Standby Threshold registers stores the delta threshold that is used to determine if a touch has  
been detected. When a touch occurs, the input signal of the corresponding sensor changes due to the  
capacitance associated with a touch. If the sensor input change exceeds the threshold settings, then  
a touch is detected.  
5.22 Sensor Base Count Registers  
Table 5.36 Sensor Base Count Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Sensor 1 Base  
Count  
50h  
R
128  
64  
32  
16  
8
4
2
1
C8h  
Sensor 2 Base  
Count  
51h  
52h  
53h  
54h  
55h  
R
R
R
R
R
128  
128  
128  
128  
128  
64  
64  
64  
64  
64  
32  
32  
32  
32  
32  
16  
16  
16  
16  
16  
8
8
8
8
8
4
4
4
4
4
2
2
2
2
2
1
1
1
1
1
C8h  
C8h  
C8h  
C8h  
C8h  
Sensor 3 Base  
Count  
Sensor 4 Base  
Count  
Sensor 5 Base  
Count  
Sensor 6 Base  
Count  
The Sensor Base Count registers store the calibrated “Not Touched” input value from the Capacitive  
Touch Sensor inputs. These registers are periodically updated by the re-calibration routine.  
The routine uses an internal adder to add the current count value for each reading to the sum of the  
previous readings until sample size has been reached. At this point, the upper 16 bits are taken and  
used as the Sensor Base Count. The internal adder is then reset and the re-calibration routine  
continues.  
The data presented is determined by the BASE_SHIFT[3:0] bits (see Section 5.5).  
APPLICATION NOTE:  
5.23 Product ID Register  
Table 5.37 Product ID Register  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Product ID  
CAP1006  
0
1
0
0
0
1
0
0
44h  
FDh  
R
Product ID  
CAP1005  
0
1
0
0
0
1
0
1
45h  
The Product ID register stores a unique 8-bit value that identifies the device.  