 浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第25页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第26页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第27页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第28页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第30页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第31页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第32页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第33页  
5 and 6 Channel Capacitive Touch Sensor  
Datasheet  
Table 5.1 Register Set in Hexadecimal Order (continued)  
REGISTER  
ADDRESS  
DEFAULT  
VALUE  
R/W  
REGISTER NAME  
FUNCTION  
PAGE  
Product ID  
CAP1006  
Stores a fixed value that identifies  
each product  
44h  
45h  
5Dh  
81h  
FDh  
R
Page 46  
Product ID  
CAP1005  
Stores a fixed value that identifies  
each product  
Stores a fixed value that identifies  
SMSC  
FEh  
FFh  
R
R
Manufacturer ID  
Revision  
Page 47  
Page 47  
Stores a fixed value that represents  
the revision number  
During Power-On-Reset (POR), the default values are stored in the registers. A POR is initiated when  
power is first applied to the part and the voltage on the VDD supply surpasses the POR level as  
specified in the electrical characteristics. Any reads to undefined registers will return 00h. Writes to  
undefined registers will not have an effect.  
5.1  
Main Status Control Register  
Table 5.2 Main Status Control Register  
ADDR  
00h  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Main Status  
Control  
R/W  
-
-
STBY  
DSLEEP  
-
-
-
INT  
00h  
The Main Status and Control register controls the primary power state of the device.  
Bit 5 - STBY - Enables Standby.  
„
„
‘0’ (default) - Sensor scanning is active.  
‘1’ - Capacitive Touch Sensor scanning is limited to the sensors set in the Standby Channel register  
(see Section 5.18). The status registers will not be cleared until read. Sensors that are no longer  
sampled will flag a release and then remain in a non-touched state.  
Bit 4 - DSLEEP - Enables Deep Sleep by deactivating all functions. This bit will be cleared when SPI  
or SMBus are received targeting the CAP1005 / CAP1006. If the CAP1005 / CAP1006 is configured  
to communicate using the BC-Link protocol, then this bit is ignored.  
„
„
‘0’ (default) - Sensor scanning is active.  
‘1’ - All sensor scanning is disabled. The status registers are automatically cleared and the INT bit  
is cleared.  
Bit 0 - INT - Indicates that there is an interrupt. This bit is only set if the ALERT# pin has been asserted.  
If a channel detects a touch and its associated interrupt enable bit is not set to a logic ‘1’ then no  
action is taken.  
This bit is cleared by writing a logic ‘0’ to it. When this bit is cleared, the ALERT# pin will be deasserted  
and all status registers will be cleared if the condition has been removed. If the WAKE/SPI_MOSI pin  
is asserted as a result of a touch detected while in Standby, it will likewise be deasserted when this  
bit is cleared.  
Note that this pin is not driven when communicating via the 4-wire SPI protocol  
„
‘0’ - No interrupt pending.  
SMSC CAP1005 / CAP1006  
Revision 1.1 (08-05-09)  
DATA2S9HEET