5 and 6 Channel Capacitive Touch Sensor
Datasheet
Table 5.12 MAX_DUR Bit Decode
MAX_DUR[3:0]
3
2
1
0
TIME BEFORE RECALIBRATION
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
560ms
840ms
1120ms
1400ms
1680ms
2240ms
2800ms
3360ms
3920ms
4480ms
5600ms
6720ms
7840ms
8906ms
10080ms
11200ms
Bits 3 - 0 - RPT_RATE[3:0] - (default 0100b) Determines the time duration between interrupt assertions
when auto repeat is enabled. The resolution is 35ms the range is from 35ms to 560ms as shown in
Table 5.13.
Table 5.13 RPT_RATE Bit Decode
RPT_RATE[3:0] OR M_PRESS[3:0]
INTERRUPT REPEAT RATE
3
2
1
0
OR M_PRESS TIME
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
35ms
70ms
105ms
140ms
175ms
210ms
245ms
SMSC CAP1005 / CAP1006
Revision 1.1 (08-05-09)
DATA3S5HEET