Commercial
Model
Load
Regulation
Initial Setpoint
Tolerance
OVP
Setpoint
Ripple and
Noise
Output
5.1 V
12 V
Current
3.8 A
GSC20-5
0.75%
0.75%
0.75%
0.75%
0.75%
2.5%
2.5%
2.5%
2.5%
2.5%
6.2 0.6 V
14 1.1 V
18.5 1.5 V
28 2.5 V
34 2.8 V
1.4%
1%
GSC20-12
GSC20-15
GSC20-24
GSC20-28
1.7 A
15 V
1.4 A
1%
24 V
0.85 A
0.7 A
1%
28 V
1%
* Add G suffix to model number for RoHS compliant model.
GSC20 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS OPERATING
NON-OPERATING
Temperature (A)
Humidity (A)
Shock (B)
See Individual Specs. -40 to +85°C
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 3 ms duration, direction,
3 orthogonal axes, total 6 shocks.
0 to 95% RH
0 to 95% RH
40 gpk
20 gpk
Altitude
-500 to 10,000 ft
1.5 g rms’0.003 g2/Hz
-500 to 40,000 ft
5 g rms’0.026 g2/Hz
Vibration (C)
SL Power Electronics, Inc. 6050 King Drive, Bldg. A, Ventura, CA 93003 USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com. Rev. 7/07.
Data Sheet © 2007 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.