Commercial
Model
Medical
Model
RoHS
Suffix*
Output
Output
Output
Total
Regulation (A)
Output No.
Output
Minimum Maximum (B) Maximum ( C ) Output Peak
Noise P-P
GPC80A
GPC80B
GPC80C
GPC80D
GPC80 E
GPC80P
GPM80A
GPM80B
GPM80C
GPM80D
GPM80E
GPM80P
G
G
G
G
G
G
1
2
3
4
+5 V
+12 V
-12 V
+12 V
1.0 A
0 A
12 A
3 A
1 A
1 A
12 A
4 A
16 A
5 A
50 mV
120 mV
120 mV
120 mV
2%
2%
3%
3%
0 A
1.2 A
1.2 A
1.2 A
1.2 A
0 A
1
2
3
4
+5 V
+12 V
-12 V
-5 V
1.0 A
0 A
0 A
0 A
12 A
3 A
1 A
1 A
12 A
4 A
1.2 A
1.2 A
16 A
5 A
1.2 A
1.2 A
50 mV
120 mV
120 mV
50 mV
2%
2%
3%
3%
1
2
3
4
+5 V
+12 V
-15 V
+15 V
1 A
0 A
0 A
0 A
12 A
3 A
1 A
1 A
12 A
4 A
1.2 A
1.2 A
16 A
5 A
1.2 A
1.2 A
50 mV
120 mV
150 mV
150 mV
2%
2%
3%
3%
1
2
3
4
+5 V
+24 V
-12 V
+12 V
1 A
0 A
0 A
0 A
12 A
2 A
1 A
1 A
12 A
3 A
1.2 A
1.2 A
16 A
4 A
1.2 A
1.2 A
50 mV
240 mV
120 mV
120 mV
2%
2%
3%
3%
1
2
3
4
+5 V
+24 V
-15 V
+15 V
1 A
0 A
0 A
0 A
12 A
2 A
1 A
1 A
12 A
3 A
1.2 A
1.2 A
16 A
4 A
1.2 A
1.2 A
50 mV
240 mV
150 mV
150 mV
2%
2%
3%
3%
1
2
3
4
+5 V
+24 V
-12 V
+12 V
1 A
0.5 A
0 A
12 A
3.5 A
1 A
12 A
4.5 A
1.2 A
2 A
16 A
4.5 A
1.2 A
2.5 A
50 mV
400 mV
120 mV
120 mV
2%
+10%/-5% D
3%
0 A
2 A
3%
GPC80-5
GPM80-5
G
G
G
G
G
G
1
1
1
1
1
1
5 V
0 A
0 A
0 A
0 A
0 A
0 A
16 A
6.7 A
5.3 A
3.4 A
2.9 A
1.7 A
20 A
9.2 A
7.3 A
4.6 A
3.9 A
2.3 A
22 A
9.2 A
7.3 A
4.6 A
3.9 A
2.3 A
50 mV
120 mV
150 mV
240 mV
280 mV
480 mV
2%
2%
2%
2%
2%
2%
GPC80-12
GPC80-15
GPC80-24
GPC80-28
GPC80-48
GPM80-12
GPM80-15
GPM80-24
GPM80-28
GPM80-48
12 V
15 V
24 V
28 V
48 V
* Add “G”suffix to part number for RoHS compliant model. Contact factory for availability.
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Ratings for unrestricted natural convection cooling; output 1 ꢀ 2 combined load not to exceed 14A continuous; total power = 80W.
C. Ratings with 26 cfm forced air cooling; output 1 ꢀ 2 combined load not to exceed 16A continuous; total power = 110W.
D. To maintain these regulation conditions, the +5V current must be at least 1/4 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted within 1%
with at least a 1A load to maintain regulation on this input.
E. For Power Fail option, add -PF after the model number.
GPC80/GPM80 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS OPERATING
NON-OPERATING
Temperature (A)
Humidity (A)
Shock (B)
See individual specs -40 to +85°C
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 3 ms duration, direction, 3
orthogonal axes, total 6 shocks.
0 to 95% RH
20 gpk
0 to 95% RH
40 gpk
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
Altitude
-500 to 10,000 ft
1.5 g rms’0.003 g2/Hz 5 g rms’0.026 g2/Hz
-500 to 40,000 ft
Vibration (C)
SL Power Electronics, Inc. 6050 King Drive, Bldg. A, Ventura, CA, 93003, USA. Phone: (805) 486 4565 Fax: (805) 487 8911 Email: sl@slpower.com Rev. 12/06.
Data Sheet © 2006 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.