内容描述: 55瓦最大连续功率 - 总计所有输出。 [55 Watts Maximum Continuous Power - Total of all Outputs.]
分类和应用: 电源电路输出元件
文件页数/大小: 2 页 / 91 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号GPM55-28的Datasheet PDF文件第1页  
OVERVOLTAGE PROTECTION:
Only output #1 is monitored for an overvoltage condition. The trip-point for a 5 volt
output is 5.6 to 6.8 volts. In some applications where an overvoltage condition could result in a hazard as defined in
applicable safety standards, redundant or additional overvoltage protection may be required. Consult factory for details.
TEMPERATURES:
The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.
OVERCURRENT PROTECTION:
The internal fuse is located in the phase lead only. EN 60601-1 requires that both
supply leads (phase and neutral) be protected against overcurrent. Complete overcurrent protection must be provided in the
host equipment. Fuse ratings must not exceed that specified for the internal fuse, must meet the requirements of EN 60601-1
and be acceptable for the country in which the host equipment is to be installed.
WARNING! RISK OF FIRE!
A blown internal fuse is an indication of catastrophic failure of circuit component(s). Repair
must be performed by SLPE authorized personnel. Refer to fuse marking on the supply for rating.
WARNING! SHOCK HAZARD!
Dangerous voltages are present on some components, printed wiring traces and heatsinks.
EXPLANATION OF SYMBOLS
Alternating Current
Attention, Consult
Accompanying Documents
Attention, Dangerous Voltages
Protective Earth (Ground)
C O N N E C T I O N S
J1 AC Input
J2 Multi-Output Models
1) Ground
1) Output 2 (+) 6) Common
3) Neutral
2) Output 2 (+) 7) Common
5) Line
3) Output 1 (+) 8) Output 4 (-)
4) Output 1 (+) 9) Output 3 (+/-)
5) Common
J2 Single Output Models
Mating Connectors
Output 1 (+) 6) Common
Amp Contact 770522-1
Output 1 (+) 7) Common J1 Amp Housing 640250-5
Output 1 (+) 8) N/C
J2 Amp Housing 640250-9
Output 1 (+) 9) N/C
Common
1)
2)
3)
4)
5)
CAUTION:
Do not exceed 5 Amps per pin on J2.
SLPE will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are
carried out by other than authorized agents of SLPE, or b) the installation of the supply is not in accordance with these installation
instructions and the applicable UL, CSA, IEC and/or EN safety standards.