GPC200 Commercial/GPM200
Medical
200 Watt Multiple Output
Commercial
Model
GPC200A
Medical
Model
GPM200A
Output No.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Output
+5 V
+12 V
-12 V
12 V (D)
+5V
+12 V
-5 V
12 V (D)
+5 V
+24 V
-12 V
12 V (D)
+5 V
+24 V
-15 V
15 V (D)
+5 V
+12 V
-12 V
5 V (D)
Output
Minimum
4A
0A
0A
0A
4A
0A
0A
0A
4A
0A
0A
0A
4A
0A
0A
0A
4A
0A
0A
0A
Output
Maximum (B)
18 A
5A
1A
3A
18 A
5A
1A
3A
18 A
3A
1A
3A
18 A
3A
1A
3A
18 A
5A
1A
3A
Output
Maximum (C)
26 A
8A
1.2 A
4A
26 A
8A
1.2 A
4A
26 A
5A
1.2 A
4A
26 A
5A
1.2 A
4A
26 A
8A
1.2 A
4A
Output Peak
32 A
12 A
1.5 A
4.5 A
32 A
12 A
1.5 A
4.5 A
32 A
6.5 A
1.5 A
4.5 A
32 A
6.5 A
1.5 A
4.5 A
32 A
12 A
1.5 A
4.5 A
Noise P-P
50 mV
120 mV
120 mV
120 mV
50 mV
120 mV
50 mV
120 mV
50 mV
240 mV
120 mV
120 mV
50 mV
240 mV
150 mV
150 mV
50 mV
120 mV
120 mV
50 mV
Total
Regulation (A)
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
GPC200B
GPM200B
GPC200D
GPM200D
GPC200E
GPM200E
GPC200F
GPM200F
A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Ratings for unrestricted natural convection cooling; outputs 1 & 2 combined load not to exceed 22A continuous; total power -150W.
C. Ratings with 26cfm forced air cooling; outputs 1 & 2 combined load not to exceed 32A continuous; total power -200W.
D. Isolated output which may be referenced as a positive or negative voltage.
GPC200/GPM200
MECHANICAL SPECIFICATIONS
Environmental
Specification
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Operating
See individual specs
0 to 95% RH
20 g
pk
-500 to 10,000 ft
1.5 g
rms
, 0.003 g
2
/Hz
Non-operating
-40 to +85
o
C
0 to 95% RH
40 g
pk
-500 to 40,000 ft
5 g
rms
, 0.026 g
2
/Hz
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com